PCS_a063 — Chg V Out Rationality
Full alert identifier: PCS_a063_chgVOutRationality
Alert description
Charger output voltage sensor mismatches high voltage processor's sensed value on CAN
Potential impact
Inability to AC charge
Set condition
Charger output voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds
Clear condition
Charger output voltage sensor value matches high voltage processor's sensed value on CAN for more than 500ms
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Chg Output V
PCS_
|
V |
Hvp Hv Link Voltage
PCS_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a063.