Skip to content

PCS_a063 — Chg V Out Rationality

Full alert identifier: PCS_a063_chgVOutRationality

Alert description

Charger output voltage sensor mismatches high voltage processor's sensed value on CAN

Potential impact

Inability to AC charge

Set condition

Charger output voltage sensor mismatches high voltage processor's sensed value on CAN for more than three seconds

Clear condition

Charger output voltage sensor value matches high voltage processor's sensed value on CAN for more than 500ms

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Chg Output V PCS_a063_chgOutputV V
Hvp Hv Link Voltage PCS_a063_hvpHvLinkVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a063.

Browse all PCS alert codes