Skip to content

PCS_a062 — Chg I Line Rationality

Full alert identifier: PCS_a062_chgILineRationality

Alert description

High DC offset present on charger input current sensor when charge functionality is not enabled. Indicates issue with vehicle if seen multiple times over multiple days.

Potential impact

Reduced AC charge rate or inability to AC charge

Set condition

Charger line current sensor DC offset exceeds threshold for more than three seconds while charging is inactive

Clear condition

Charger line current sensor DC offset is below clear threshold for more than 500ms

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Chg Input I Offset PCS_a062_chgInputIOffset A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a062.

Browse all PCS alert codes