PCS_a062 — Chg I Line Rationality
Full alert identifier: PCS_a062_chgILineRationality
Alert description
High DC offset present on charger input current sensor when charge functionality is not enabled. Indicates issue with vehicle if seen multiple times over multiple days.
Potential impact
Reduced AC charge rate or inability to AC charge
Set condition
Charger line current sensor DC offset exceeds threshold for more than three seconds while charging is inactive
Clear condition
Charger line current sensor DC offset is below clear threshold for more than 500ms
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Chg Input I Offset
PCS_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of PCS_a062.