Secondary steering feedback actuator monitor alerts
Browse 102 SSFAM alert codes and open an entry for its description and recorded conditions.
SSFAM alert codes
Showing 51–100 of 102
- SSFAM_a111 — EPBR MIA SSFAM_a111_EPBR_MIA One or more of the messages the vehicle controller receives periodically from the right Electronic Park Brake (EPBR) electronic control unit (ECU) is not received, indicating the EPBR ECU may be unavailable (MIA).
- SSFAM_a112 — EPBL MIA SSFAM_a112_EPBL_MIA One or more of the messages the vehicle controller receives periodically from the left Electronic Park Brake (EPBL) electronic control unit (ECU) is not received, indicating the EPBL ECU may be unavailable (MIA).
- SSFAM_a113 — UI MIA SSFAM_a113_UI_MIA One or more of the expected CAN messages from UI were not received.
- SSFAM_a114 — ESP MIA SSFAM_a114_ESP_MIA One or more expected Controller Area Network (CAN) messages from the Electronic Stability Program (ESP) electronic control unit (ECU) was not received. Stability and traction control functions may be unavailable, or their performance may b…
- SSFAM_a115 — VCRIGHT1 MIA SSFAM_a115_VCRIGHT1_MIA One or more of the messages the vehicle controller receives periodically from the right vehicle controller (VCRIGHT1) is not received, indicating the VCRIGHT1 may be unavailable (MIA).
- SSFAM_a116 — VCLEFT MIA SSFAM_a116_VCLEFT_MIA One or more of the messages the vehicle controller receives periodically from the left vehicle controller (VCLEFT) is not received, indicating the VCLEFT may be unavailable (MIA).
- SSFAM_a117 — VCRIGHT MIA SSFAM_a117_VCRIGHT_MIA One or more of the messages the vehicle controller receives periodically from the right vehicle controller (VCRIGHT) is not received, indicating the VCRIGHT may be unavailable (MIA).
- SSFAM_a118 — VCLEFT1 MIA SSFAM_a118_VCLEFT1_MIA One or more of the messages the vehicle controller receives periodically from the left vehicle controller (VCLEFT1) is not received, indicating the VCLEFT1 may be unavailable (MIA).
- SSFAM_a119 — SCCM MIA SSFAM_a119_SCCM_MIA One or more of the messages the vehicle controller receives periodically from the Steering Column Control Module (SCCM) is not received, indicating the SCCM may be unavailable (MIA).
- SSFAM_a120 — DI DRIVE MIA SSFAM_a120_DI_DRIVE_MIA One or more of the messages the vehicle controller receives periodically from the drive interface (DI) electronic control unit (ECU) is not received while the vehicle is in Drive, indicating the DI ECU may be unavailable (MIA).
- SSFAM_a124 — VCLEFT2 MIA SSFAM_a124_VCLEFT2_MIA One or more of the messages the vehicle controller receives periodically from the left vehicle controller (VCLEFT2) is not received, indicating the VCLEFT1 may be unavailable (MIA).
- SSFAM_a125 — EGGRIGHT1 MIA SSFAM_a125_EGGRIGHT1_MIA One or more of the expected CAN messages from the Etherloop Generalized Gateway Right (Core 1) were not received, indicating the EGGRIGHT1 ECU may be unavailable (MIA).
- SSFAM_a127 — EGGREAR1 MIA SSFAM_a127_EGGREAR1_MIA One or more of the expected CAN messages from the Etherloop Generalized Gateway Rear (Core 1) were not received, indicating the EGGREAR1 ECU may be unavailable (MIA).
- SSFAM_a128 — VCREAR MIA SSFAM_a128_VCREAR_MIA One or more of the messages the vehicle controller receives periodically from the rear vehicle controller (VCREAR) is not received, indicating the VCREAR may be unavailable (MIA).
- SSFAM_a129 — Controller Speed Mismatch SSFAM_a129_controllerSpeedMismatch Monitor and controller have mismatched speed input
- SSFAM_a130 — Mag Sense Angle Sensor Fault SSFAM_a130_magSenseAngleSensorFault The motor angle sensor signaled an error, or cannot be monitored.
- SSFAM_a132 — Roadwheel CF Mismatch SSFAM_a132_roadwheelCFMismatch The monitors calculated control flow doesn't match the controllers desired control flow
- SSFAM_a133 — Handwheel CF Mismatch SSFAM_a133_handwheelCFMismatch The monitors calculated control flow doesn't match the controllers desired control flow
- SSFAM_a135 — Motor Uncalibrated SSFAM_a135_motorUncalibrated The monitor is missing calibration data for the motor.
- SSFAM_a136 — Motor Calibration Mismatch SSFAM_a136_motorCalibrationMismatch The motor calibration data does not match across controller and monitor.
- SSFAM_a139 — Handwheel Uncalibrated SSFAM_a139_handwheelUncalibrated The monitor is missing calibration data for the handwheel.
- SSFAM_a140 — Handwheel Calibration Mismatch SSFAM_a140_handwheelCalibrationMismatch The handwheel calibration data does not match across controller and monitor.
- SSFAM_a142 — Monitor Trip SSFAM_a142_monitorTrip A monitor trip has been detected, system will degrade
- SSFAM_a151 — Insufficient Torque Error SSFAM_a151_insufficientTorqueError The monitors calculated handwheel minimum feedback expectation is higher than the torque produced
- SSFAM_a153 — Inadvertent Torque Error SSFAM_a153_inadvertentTorqueError The monitors calculated handwheel maximum motoring torque expectation has been breached by the motor
- SSFAM_a155 — Overgain Torque Error SSFAM_a155_overgainTorqueError The monitors calculated handwheel maximum torque expectation has been breached
- SSFAM_a156 — Handwheel Torque Est Error SSFAM_a156_handwheelTorqueEstError The monitors torque estimate differs from the controllers torque estimate
- SSFAM_a157 — Handwheel Feedback Acc Error SSFAM_a157_handwheelFeedbackAccError The monitor detected the handwheel torque production of its paired controller
- SSFAM_a158 — Torque Follower Monitor SSFAM_a158_torqueFollowerMonitor The monitor detected an error in the torque production of its paired controller
- SSFAM_a161 — Gate Driver Config Error SSFAM_a161_gateDriverConfigError The monitor detected an error in the gate driver config being set by its paired controller
- SSFAM_a163 — Calibration Fault SSFAM_a163_calibrationFault The steering monitor detected an error affecting its calibration
- SSFAM_a166 — Simple Feedback Error SSFAM_a166_simpleFeedbackError The handwheel feedback torque is not damping nor returning
- SSFAM_a168 — Handwheel Torque Est Warning SSFAM_a168_handwheelTorqueEstWarning The monitors torque estimate differs from the controllers torque estimate
- SSFAM_a169 — Return Target Error SSFAM_a169_returnTargetError The monitor detected an error with the targeted handwheel return position of the controller
- SSFAM_a170 — Simple Feedback Warning SSFAM_a170_simpleFeedbackWarning The handwheel feedback torque is not damping nor returning
- SSFAM_a171 — Insufficient Torque Warning SSFAM_a171_insufficientTorqueWarning The monitors calculated handwheel minimum feedback expectation is higher than the torque produced
- SSFAM_a172 — Overgain Torque Warning SSFAM_a172_overgainTorqueWarning The monitors calculated handwheel maximum torque expectation has been breached
- SSFAM_a173 — Inadvertent Torque Warning SSFAM_a173_inadvertentTorqueWarning The monitors calculated handwheel maximum motoring torque expectation has been breached by the motor
- SSFAM_a174 — Torque Follower Monitor Warning SSFAM_a174_torqueFollowerMonitorWarning The monitor detected a warning in the torque production of its paired controller
- SSFAM_a177 — Torque Not Expected Error SSFAM_a177_torqueNotExpectedError The monitor detected an error in the measured torque output of its paired controller
- SSFAM_a180 — Handwheel Feedback Acc Warning SSFAM_a180_handwheelFeedbackAccWarning The monitor detected the handwheel torque production of its paired controller
- SSFAM_a200 — Nvm Save Timed Out SSFAM_a200_nvmSaveTimedOut Power down NVM save reached max allowed time
- SSFAM_a208 — Startup Sequence Failed2 SSFAM_a208_startupSequenceFailed2 Power steering startup sequence is unsuccessful.
- SSFAM_a209 — Startup Sequence Failed SSFAM_a209_startupSequenceFailed Power steering startup sequence is unsuccessful.
- SSFAM_a211 — Adc0 Regs1 SSFAM_a211_adc0Regs1 Debug alert containing ADC0 register data to root cause intermittent startup failure.
- SSFAM_a212 — Adc0 Regs2 SSFAM_a212_adc0Regs2 Debug alert containing ADC0 register data to root cause intermittent startup failure.
- SSFAM_a213 — Roadwheel CF Mismatch Warning SSFAM_a213_roadwheelCFMismatchWarning The monitors calculated control flow doesn't match the controllers desired control flow
- SSFAM_a214 — Handwheel CF Mismatch Warning SSFAM_a214_handwheelCFMismatchWarning The monitors calculated control flow doesn't match the controllers desired control flow
- SSFAM_a227 — Challenge Failed SSFAM_a227_challengeFailed Monitor micro didn't respond with the correct answer given the controllers randomly generated challenge
- SSFAM_a228 — Challenge Failed2 SSFAM_a228_challengeFailed2 Monitor micro didn't respond with the correct answer given the controllers randomly generated challenge