Skip to content

SSFAM_a209 — Startup Sequence Failed

Full alert identifier: SSFAM_a209_startupSequenceFailed

Alert description

Power steering startup sequence is unsuccessful.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Monitor calibration check is unsuccessful, corresponding controller is not responding, or state timeout occurs.

Clear condition

Startup sequence passes. Startup sequence is run during vehicle startup, and the condition may resolve by drive cycling the vehicle.

Signals to check

These diagnostic fields are associated with SSFAM_a209. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Controller Startup Failed SSFAM_a209_controllerStartupFailed —
D Axis Current Detected SSFAM_a209_dAxisCurrentDetected A
D Axis Current Expected SSFAM_a209_dAxisCurrentExpected A
Failed State SSFAM_a209_failedState —
State Timeout Exceeded SSFAM_a209_stateTimeoutExceeded —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFAM_a209.

Browse all SSFAM alert codes