SSFAM_a208 — Startup Sequence Failed2

Full alert identifier: SSFAM_a208_startupSequenceFailed2

Alert description

Power steering startup sequence is unsuccessful.

Potential impact

The motor is disqualified and system health is degraded.

Set condition

Monitor calibration check is unsuccessful, corresponding controller is not responding, or state timeout occurs.

Clear condition

Startup sequence passes. Startup sequence is run during vehicle startup, and the condition may resolve by drive cycling the vehicle.

Signals to check

These diagnostic fields are associated with SSFAM_a208. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Bus Voltage SSFAM_a208_busVoltage V
Phase A Current SSFAM_a208_phaseACurrent A
Phase B Current SSFAM_a208_phaseBCurrent A
Phase C Current SSFAM_a208_phaseCCurrent A
Torque Estimate Valid SSFAM_a208_torqueEstimateValid —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFAM_a208.

Browse all SSFAM alert codes