Skip to content

SSFAM_a136 — Motor Calibration Mismatch

Full alert identifier: SSFAM_a136_motorCalibrationMismatch

Alert description

The motor calibration data does not match across controller and monitor.

Potential impact

Torque from motor is unavailable

Set condition

Controller and monitor handwheel calibration data not matching

Clear condition

Controller and monitor handwheel calibration data matching

Signals to check

These diagnostic fields are associated with SSFAM_a136. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Pm Flux SSFAM_a136_pmFlux Wb
Pm Flux Mismatch SSFAM_a136_pmFluxMismatch —
Stator Offset SSFAM_a136_statorOffset rad
Stator Offset Mismatch SSFAM_a136_statorOffsetMismatch —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFAM_a136.

Browse all SSFAM alert codes