Skip to content

SSFAM_a140 — Handwheel Calibration Mismatch

Full alert identifier: SSFAM_a140_handwheelCalibrationMismatch

Alert description

The handwheel calibration data does not match across controller and monitor.

Potential impact

Steering control from this node is disabled

Set condition

Controller and monitor handwheel calibration data not matching

Clear condition

Controller and monitor handwheel calibration data matching

Signals to check

These diagnostic fields are associated with SSFAM_a140. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Zero Offset SSFAM_a140_zeroOffset rad
Zero Offset Mismatch SSFAM_a140_zeroOffsetMismatch —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SSFAM_a140.

Browse all SSFAM alert codes