Skip to content

CP_a103 — Proximity Pe Disconnected

Full alert identifier: CP_a103_proximityPeDisconnected

Alert description

The charge port (CP) electronic control unit (ECU) detects that the protective earth connection may be missing.

Potential impact

Charging does not start.

Set condition

The CP ECU detects proximity voltage greater than 4.75V for more than 100ms.

Clear condition

The CP ECU detects proximity voltage in the disconnected range for more than 200ms.

Signals to check

These diagnostic fields are associated with CP_a103. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Proximity V CP_a103_proximityV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a103.