Skip to content

CP_a005 — Gbdc Live Disconnect

Full alert identifier: CP_a005_gbdcLiveDisconnect

Alert description

The charge port (CP) electronic control unit (ECU) has detected that a GB (Charging standard used in China) CC1 or CC2 charger disconnected unexpectedly during charge.

Potential impact

Charging may be interrupted unexpectedly, and there could be damage to the charge inlet if the charge cable is disconnected while under load.

Set condition

The CP ECU detects that CC1 or CC2 is disconnected while in the active GB DC charging state.

Clear condition

The CP door inductive sensor reports that the CP door is closed.

Signals to check

These diagnostic fields are associated with CP_a005. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cc 1 Voltage CP_a005_cc1Voltage V
Cc 2 Voltage CP_a005_cc2Voltage V
Evse Current CP_a005_evseCurrent A
Gbdc State CP_a005_gbdcState —
Latch Engaged CP_a005_latchEngaged —
Pack Current CP_a005_packCurrent A
Supercharger Connected CP_a005_superchargerConnected —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a005.

Browse all CP alert codes