Skip to content

CP_a084 — Prox Pe Disconnected gb

Full alert identifier: CP_a084_proxPeDisconnected_gb

Alert description

The charge port (CP) electronic control unit (ECU) detects that the GB DC or AC protective earth (PE) busbar is missing.

Potential impact

GB DC charging does not start.

Set condition

The CP ECU detects that GB AC proximity voltage is greater than 4.75V for more than 100ms.

Clear condition

The CP ECU detects that proximity voltages for both the GB AC and GB DC inlets are within the nominal cable disconnected range for more than 200ms.

Signals to check

These diagnostic fields are associated with CP_a084. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cc 1 Voltage CP_a084_cc1Voltage V
Cc 2 Voltage CP_a084_cc2Voltage V
Proximity V CP_a084_proximityV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a084.