CP_a084 — Prox Pe Disconnected gb
Full alert identifier: CP_a084_proxPeDisconnected_gb
Alert description
The charge port (CP) electronic control unit (ECU) detects that the GB DC or AC protective earth (PE) busbar is missing.
Potential impact
GB DC charging does not start.
Set condition
The CP ECU detects that GB AC proximity voltage is greater than 4.75V for more than 100ms.
Clear condition
The CP ECU detects that proximity voltages for both the GB AC and GB DC inlets are within the nominal cable disconnected range for more than 200ms.
Signals to check
These diagnostic fields are associated with CP_a084. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Cc 1 Voltage
CP_
|
V |
Cc 2 Voltage
CP_
|
V |
Proximity V
CP_
|
V |