Skip to content

CP_a056 — Prox Disconnected

Full alert identifier: CP_a056_proxDisconnected

Alert description

Proximity circuit was opened unexpectedly while charging. Charging may be interrupted.

Potential impact

Charging may be interrupted unexpectedly.

Set condition

The charge port (CP) detects that there is no charge cable present while the vehicle is charging.

Clear condition

Any charge port (CP) door sensor detects that the door is closed.

Signals to check

These diagnostic fields are associated with CP_a056. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
CHG Insert Enable CP_a056_CHG_InsertEnable —
CP Latch Enable Cmd CP_a056_CP_latchEnableCmd —
CP Proximity CP_a056_CP_proximity
0
SNA
1
DISCONNECTED
2
UNLATCHED
3
LATCHED
—
Latch State CP_a056_latchState
0
SNA
1
DISENGAGED
2
ENGAGED
3
BLOCKING
—
Pack Current CP_a056_packCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a056.

Browse all CP alert codes