CP_a056 — Prox Disconnected
Full alert identifier: CP_a056_proxDisconnected
Alert description
Proximity circuit was opened unexpectedly while charging. Charging may be interrupted.
Potential impact
Charging may be interrupted unexpectedly.
Set condition
The charge port (CP) detects that there is no charge cable present while the vehicle is charging.
Clear condition
Any charge port (CP) door sensor detects that the door is closed.
Signals to check
These diagnostic fields are associated with CP_a056. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
CHG Insert Enable
CP_
|
— |
CP Latch Enable Cmd
CP_
|
— |
CP Proximity
CP_
|
— |
Latch State
CP_
|
— |
Pack Current
CP_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a056.