CP_a004 — Proximity Rationality

Full alert identifier: CP_a004_proximityRationality

Alert description

The charge port (CP) electronic control unit (ECU) detects proximity voltage in an unexpected range.

Potential impact

If the issue is with the vehicle, it will not be able to charge.

Set condition

The CP ECU detects that proximity voltage is outside of the expected range.

Clear condition

The CP ECU detects that proximity voltage enters the expected range.

Signals to check

These diagnostic fields are associated with CP_a004. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Cc 1 Voltage CP_a004_cc1Voltage V
Cc 2 Voltage CP_a004_cc2Voltage V
Proximity V CP_a004_proximityV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a004.