CP_a042 — Door Assembly Broken
Full alert identifier: CP_a042_doorAssemblyBroken
Alert description
The charge port (CP) electronic control unit (CPU) detects an issue with the charge port door assembly.
Potential impact
The charge port door does not actuate as expected.
Set condition
The CP door potentiometer reads greater than 90% for more than 2 seconds or the potentiometer reading wraps around.
Clear condition
The CP door potentiometer reports a reading of 90% for more than 1 second, and the reading does not wrap around for more than 4 seconds.
Signals to check
These diagnostic fields are associated with CP_a042. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Door Counts
CP_
|
% |
Hall Sensor Filtered
CP_
|
V |
Inductive Sensor Filtered
CP_
|
Hz |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a042.