Skip to content

CP_a043 — Door Pot Irrational

Full alert identifier: CP_a043_doorPotIrrational

Alert description

The charge port (CP) electronic control unit (ECU) detects an issue with the CP door potentiometer.

Potential impact

The CP door does not open or close as designed.

Set condition

The CP ECU detects that the CP door potentiometer is behaving erratically, based on sensor readings.

Clear condition

The CP ECU detects via potentiometer sensor readings that the CP door behaves rationally through several open and close cycles.

Signals to check

These diagnostic fields are associated with CP_a043. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Door Pot Filtered CP_a043_doorPotFiltered %
Door Velocity CP_a043_doorVelocity %/s
Drift Flag CP_a043_driftFlag —
Idle Door Pot CP_a043_idleDoorPot %
Out Of Range Flag CP_a043_outOfRangeFlag —
Wrong Direction Flag CP_a043_wrongDirectionFlag —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a043.

Browse all CP alert codes