CP_a068 — Door Sensor Mismatch
Full alert identifier: CP_a068_doorSensorMismatch
Alert description
The charge port (CP) electronic control unit (ECU) detects that the presence sensor and potentiometer readings of the CP door position do not match.
Potential impact
The charge port door may not open when pressed.
Set condition
The CP door position readings from the presence sensor and potentiometer do not match.
Clear condition
The CP door position readings from the presence sensor and potentiometer match.
Signals to check
These diagnostic fields are associated with CP_a068. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Door Closed
CP_
|
— |
Door Counts Filtered
CP_
|
% |
Door Present
CP_
|
— |
Hall Sensor Filtered
CP_
|
V |
Inductive Sensor Filtered
CP_
|
Hz |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a068.