CP_a070 — Door Inductive Sensor Reset
Full alert identifier: CP_a070_doorInductiveSensorReset
Alert description
The charge port (CP) electronic control unit (ECU) reset the CP door inductive sensor due to a I2C communication or conversion error.
Potential impact
The CP door may not function as expected.
Set condition
The CP door inductive sensor encounters a I2C communication or conversion error, causing the ECU to reset it.
Clear condition
Clears automatically.
Signals to check
These diagnostic fields are associated with CP_a070. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
I 2 C IBCR
CP_
|
— |
I 2 C IBSR
CP_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a070.