CP_a041 — Door Sensor Unplugged
Full alert identifier: CP_a041_doorSensorUnplugged
Alert description
The charge port (CP) electronic control unit (ECU) detects that the charge port door sensor is unplugged.
Potential impact
The CP door does not actuate properly.
Set condition
The CP door potentiometer reads less than 1% for more than 2 seconds.
Clear condition
The CP door potentiometer reads greater than 1% for more than 1 second.
Signals to check
These diagnostic fields are associated with CP_a041. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Door Counts
CP_
|
% |
Hall Sensor Filtered
CP_
|
V |
Inductive Sensor Filtered
CP_
|
Hz |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a041.