Skip to content

CP_a051 — Door Inductive Sensor MIA

Full alert identifier: CP_a051_doorInductiveSensorMIA

Alert description

The charge port (CP) electronic control unit (ECU) detects that communication with the CP door inductive sensor has failed.

Potential impact

Push-to-open does not work, and the charge port does not detect that the high voltage (HV) inlet is covered by the CP door.

Set condition

The CP ECU loses inter-integrated circuit (I2C) communication with the inductive door sensor, and attempts to reestablish communication have failed.

Clear condition

The CP ECU reestablished communication with the CP door inductive sensor.

Signals to check

These diagnostic fields are associated with CP_a051. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Door Counts Filtered CP_a051_doorCountsFiltered %

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a051.

Browse all CP alert codes