CP_a051 — Door Inductive Sensor MIA
Full alert identifier: CP_a051_doorInductiveSensorMIA
Alert description
The charge port (CP) electronic control unit (ECU) detects that communication with the CP door inductive sensor has failed.
Potential impact
Push-to-open does not work, and the charge port does not detect that the high voltage (HV) inlet is covered by the CP door.
Set condition
The CP ECU loses inter-integrated circuit (I2C) communication with the inductive door sensor, and attempts to reestablish communication have failed.
Clear condition
The CP ECU reestablished communication with the CP door inductive sensor.
Signals to check
These diagnostic fields are associated with CP_a051. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Door Counts Filtered
CP_
|
% |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a051.