CP_a171 — Bed Outlet Door Irrational
Full alert identifier: CP_a171_bedOutletDoorIrrational
Alert description
The charge port (CP) detects that the bed outlet door sensor is irrational, resulting in the bed outlets being permanently turned off.
Potential impact
The bed outlets will not be functional.
Set condition
The CP detects the bed outlet door sensor is reporting values outside the nominal range.
Clear condition
The CP detects the bed outlet door sensor is reporting values within the nominal range.
Signals to check
These diagnostic fields are associated with CP_a171. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Bed Outlet Door V Interval Max 10 S
CP_
|
V |
Bed Outlet Door V Interval Min 10 S
CP_
|
V |
Current Bed Outlet Door V
CP_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a171.