CP_a109 — Thermistor Irrational

Full alert identifier: CP_a109_thermistorIrrational

Alert description

Thermistor input is open or short circuit

Potential impact

Charging and heating functions do not work as expected.

Set condition

The thermistor reports a voltage less than the open circuit threshold and, if short circuit detection is supported, greater than the short circuit threshold for at least one second.

Clear condition

The thermistor reports a voltage greater than the open circuit threshold or, if short circuit detection is supported, less than the short circuit threshold for at least one second.

Signals to check

These diagnostic fields are associated with CP_a109. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Thermistor Id CP_a109_thermistorId —
Thermistor Temp CP_a109_thermistorTemp C

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a109.