CP_a031 — Door Closed Commanded Open
Full alert identifier: CP_a031_doorClosedCommandedOpen
Alert description
Charge port (CP) door is expected to be open but is still closed.
Potential impact
Charge port door may not open correctly.
Set condition
Charge port (CP) door is not detected as open, even after it has been commanded to open.
Clear condition
Charge port (CP) door is detected as open or is requested to close.
Signals to check
These diagnostic fields are associated with CP_a031. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Aps Voltage
CP_
|
V |
Door Counts Filtered
CP_
|
% |
Hall Sensor Filtered
CP_
|
V |
Inductive Sensor Filtered
CP_
|
Hz |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a031.