CP_a032 — Door Open Expected Closed
Full alert identifier: CP_a032_doorOpenExpectedClosed
Alert description
Charge port (CP) door is expected to be closed but is still open.
Potential impact
Charge port door may not close properly.
Set condition
Charge port (CP) door is not detected as closed, even after it has been commanded to close.
Clear condition
Charge port (CP) door is detected as closed or is requested to open.
Signals to check
These diagnostic fields are associated with CP_a032. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Aps Voltage
CP_
|
V |
Door Counts Filtered
CP_
|
% |
Hall Sensor Filtered
CP_
|
V |
Inductive Sensor Filtered
CP_
|
Hz |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a032.