Skip to content

VCLEFT_a354 — eFuse Mgmt Lift Gate

Full alert identifier: VCLEFT_a354_eFuseMgmtLiftGate

Alert description

Unexpected voltage seen on liftgate strut output. Liftgate strut may be disabled

Potential impact

Liftgate control may be disabled

Set condition

Voltage is above 8V for 200ms on the liftgate strut output while it is not being driven

Clear condition

10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset

Signals to check

These diagnostic fields are associated with VCLEFT_a354. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
E Fuse Trip Count VCLEFT_a354_eFuseTripCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a354.

Browse all VCLEFT alert codes