VCLEFT_a354 — eFuse Mgmt Lift Gate
Full alert identifier: VCLEFT_a354_eFuseMgmtLiftGate
Alert description
Unexpected voltage seen on liftgate strut output. Liftgate strut may be disabled
Potential impact
Liftgate control may be disabled
Set condition
Voltage is above 8V for 200ms on the liftgate strut output while it is not being driven
Clear condition
10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset
Signals to check
These diagnostic fields are associated with VCLEFT_a354. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
E Fuse Trip Count
VCLEFT_
|
— |
Check other alerts