Skip to content

VCLEFT_a353 — eFuse Mgmt Steering Column

Full alert identifier: VCLEFT_a353_eFuseMgmtSteeringColumn

Alert description

Unexpected voltage seen on steering column motor outputs. Steering column motors may be disabled

Potential impact

Steering column control may be disabled

Set condition

Voltage is above 8V for 200ms on at least one of the steering column motor outputs while none of them are being driven

Clear condition

10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset

Signals to check

These diagnostic fields are associated with VCLEFT_a353. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
E Fuse Trip Count VCLEFT_a353_eFuseTripCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a353.

Browse all VCLEFT alert codes