VCLEFT_a303 — eFuse Mgmt Window Lift
Full alert identifier: VCLEFT_a303_eFuseMgmtWindowLift
Alert description
Unexpected voltage seen on window motor outputs. Window motors may be disabled
Potential impact
Left window control may be disabled
Set condition
Voltage is above 8V for 200ms on at least one of the left window motor outputs while none of them are being driven
Clear condition
10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset
Signals to check
These diagnostic fields are associated with VCLEFT_a303. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
E Fuse Trip Count
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a303.