VCLEFT_a346 — eFuse Mgmt Vbat Fused2
Full alert identifier: VCLEFT_a346_eFuseMgmtVbatFused2
Alert description
Unexpected voltage seen on non-continuous device outputs. Left mirror fold and tilt, and steering column motors may be disabled. This alert excludes windows, and operates on different ECU hardware revisions compared to the eFuseMgmtVbatFused alert.
Potential impact
Left mirror fold and tilt, and steering column motor control may be disabled
Set condition
Voltage is above 8V for 200ms on at least one of the following device outputs while none of them are being driven: left mirror fold and tilt, and steering column motors
Clear condition
10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset
Signals to check
These diagnostic fields are associated with VCLEFT_a346. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
E Fuse Trip Count
VCLEFT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a346.