Skip to content

VCLEFT_a346 — eFuse Mgmt Vbat Fused2

Full alert identifier: VCLEFT_a346_eFuseMgmtVbatFused2

Alert description

Unexpected voltage seen on non-continuous device outputs. Left mirror fold and tilt, and steering column motors may be disabled. This alert excludes windows, and operates on different ECU hardware revisions compared to the eFuseMgmtVbatFused alert.

Potential impact

Left mirror fold and tilt, and steering column motor control may be disabled

Set condition

Voltage is above 8V for 200ms on at least one of the following device outputs while none of them are being driven: left mirror fold and tilt, and steering column motors

Clear condition

10 seconds after the alert sets. There is a maximum of 3 retries before loads are disabled until an ECU reset

Signals to check

These diagnostic fields are associated with VCLEFT_a346. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
E Fuse Trip Count VCLEFT_a346_eFuseTripCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a346.

Browse all VCLEFT alert codes