Skip to content

VCFRONT_a124 — Pump Pt IC Warning

Full alert identifier: VCFRONT_a124_pumpPtICWarning

Alert description

The front vehicle controller (VCFRONT) detects LV8907 integrated circuit on the powertrain pump motor issued a warning, which may prevent the powertrain pump from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

The LV8907 integrated circuit on the on the powertrain pump motor issues a circuit warning that prevents the motor controller from driving the motor.

Clear condition

The LV8907 integrated circuit on the powertrain pump motor no longer issues a circuit warning that prevents the motor controller from driving the motor.

Signals to check

These diagnostic fields are associated with VCFRONT_a124. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Junction Over Temp VCFRONT_a124_junctionOverTemp —
Junction Temp Warning VCFRONT_a124_junctionTempWarning —
Loss Of Speed Lock VCFRONT_a124_lossOfSpeedLock —
Start Up Operation VCFRONT_a124_startUpOperation —
Vcc Under Voltage VCFRONT_a124_vccUnderVoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a124.

Browse all VCFRONT alert codes