Skip to content

VCFRONT_a123 — Pump Pt IC Latch Fault

Full alert identifier: VCFRONT_a123_pumpPtICLatchFault

Alert description

The front vehicle controller (VCFRONT) detects the LV8907 integrated circuit on the powertrain pump is experiencing an electrical condition (short or disconnect), which may prevent the powertrain pump from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

The LV8907 integrated circuit on the powertrain pump motor experiences an electrical condition (short or disconnect) that prevents the motor controller from driving the motor.

Clear condition

The LV8907 integrated circuit on the powertrain pump motor resets or no longer experiences an electrical condition (short or disconnect) that prevents the motor controller from driving the motor.

Signals to check

These diagnostic fields are associated with VCFRONT_a123. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Fet Short Circuit VCFRONT_a123_fetShortCircuit —
Locked Rotor VCFRONT_a123_lockedRotor —
Over Current Error VCFRONT_a123_overCurrentError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a123.

Browse all VCFRONT alert codes