VCFRONT_a121 — Pump Chiller IC Latch Fault

Full alert identifier: VCFRONT_a121_pumpChillerICLatchFault

Alert description

The front vehicle controller (VCFRONT) detects the LV8907 integrated circuit on the chiller pump motor is experiencing an electrical condition (short or disconnect), which may prevent the chiller pump from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

The LV8907 integrated circuit on the chiller pump motor experiences an electrical condition (short or disconnect) that prevents the motor controller from driving the motor.

Clear condition

The LV8907 integrated circuit on the chiller pump motor resets or no longer experiences an electrical condition (short or disconnect) that prevents the motor controller from driving the motor.

Signals to check

These diagnostic fields are associated with VCFRONT_a121. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Fet Short Circuit VCFRONT_a121_fetShortCircuit —
Locked Rotor VCFRONT_a121_lockedRotor —
Over Current Error VCFRONT_a121_overCurrentError —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a121.