Skip to content

VCFRONT_a122 — Pump Chiller IC Warning

Full alert identifier: VCFRONT_a122_pumpChillerICWarning

Alert description

The front vehicle controller (VCFRONT) detects the LV8907 integrated circuit on the chiller pump issued a warning, which may prevent the chiller pump from running as expected.

Potential impact

Powertrain performance may be limited.

Set condition

The LV8907 integrated circuit on the on the chiller pump motor issues a circuit warning that prevents the motor controller from driving the motor.

Clear condition

The LV8907 integrated circuit on the chiller pump motor no longer issues a circuit warning that prevents the motor controller from driving the motor.

Signals to check

These diagnostic fields are associated with VCFRONT_a122. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Junction Over Temp VCFRONT_a122_junctionOverTemp —
Junction Temp Warning VCFRONT_a122_junctionTempWarning —
Loss Of Speed Lock VCFRONT_a122_lossOfSpeedLock —
Start Up Operation VCFRONT_a122_startUpOperation —
Vcc Under Voltage VCFRONT_a122_vccUnderVoltage —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a122.

Browse all VCFRONT alert codes