Tesla restraints control module alerts
Browse 705 TRCM alert codes and open an entry for its description and recorded conditions.
TRCM alert codes
Showing 1–50 of 705
- TRCM_a001 — Airbags Disabled TRCM_a001_airbagsDisabled Restraint Control Module (RCM) is disarmed and airbags are disabled. This alert indicates that the Safety Restraint System is not ready to deploy airbags and other safety devices in the event of a collision.
- TRCM_a002 — System Disabled TRCM_a002_systemDisabled Restraint Control Module (RCM) system is disabled due to a critical system error. This alert indicates that the Safety Restraint System has detected a condition that prevents normal operation.
- TRCM_a003 — SW Assertion TRCM_a003_SWAssertion An internal software assertion has failed.
- TRCM_a004 — Internal Failure TRCM_a004_internalFailure Restraint Control Module (RCM) non-servicable internal condition detected. This alert indicates that the RCM has detected an internal condition that may affect its ability to operate properly.
- TRCM_a005 — CANTX Error TRCM_a005_CANTXError An error has been detected with CAN transmission. Used by engineering to debug.
- TRCM_a006 — CANTX cyclic Error TRCM_a006_CANTX_cyclicError An error has been detected within the CANTX cyclic dispatcher generated code. Used by engineering to debug.
- TRCM_a007 — Chassis Checksum Error TRCM_a007_chassisChecksumError CH Bus - Checksum Error
- TRCM_a008 — Chassis Counter Error TRCM_a008_chassisCounterError Chassis Bus - Counter Error
- TRCM_a009 — Party Checksum Error TRCM_a009_partyChecksumError PARTY Bus - Checksum Error
- TRCM_a010 — Party Counter Error TRCM_a010_partyCounterError PARTY Bus - Counter Error
- TRCM_a011 — Edr Data Locked TRCM_a011_edrDataLocked EDR data locked
- TRCM_a011 — Front Crash Algo Wakeup TRCM_a011_frontCrashAlgoWakeup The front crash algorithm has woken up.
- TRCM_a012 — Asm5 Temperature Error TRCM_a012_asm5TemperatureError TRCM failure due to inability to confirm ASM5 temperature is inside operating range
- TRCM_a012 — Asm5 Temperature Outside Signal Range TRCM_a012_asm5TemperatureOutsideSignalRange TRCM failure due to ASM5 sensor temperature outside expected measurement range
- TRCM_a013 — Alert Manager Fault TRCM_a013_AlertManagerFault Alert Manager encountered an internal processing error.
- TRCM_a014 — Asm3 Temperature Error TRCM_a014_asm3TemperatureError TRCM failure due to inability to confirm ASM3 temperature is inside operating range
- TRCM_a014 — Asm3 Temperature Outside Signal Range TRCM_a014_asm3TemperatureOutsideSignalRange TRCM failure due to ASM3 sensor temperature outside expected measurement range
- TRCM_a015 — NVMM Error TRCM_a015_NVMMError An issue is indicated from the non-volatile memory manager.
- TRCM_a016 — NVMM Record Error TRCM_a016_NVMMRecordError An issue is indicated from a particular non-volatile memory record.
- TRCM_a017 — Asm5 Temperature Outside Operating Range TRCM_a017_asm5TemperatureOutsideOperatingRange ASM5 inertial sensor temperature exceeds the sensor's operating range. This alert indicates that the sensor is operating outside its specified temperature limits, which may affect measurement accuracy.
- TRCM_a018 — Asm3 Temperature Outside Operating Range TRCM_a018_asm3TemperatureOutsideOperatingRange ASM3 inertial sensor temperature exceeds the sensor's operating range. This alert indicates that the sensor is operating outside its specified temperature limits, which may affect measurement accuracy.
- TRCM_a019 — Task500us Error TRCM_a019_Task500usError Debug information for 500us task errors.
- TRCM_a020 — Asm3 Com Status Error TRCM_a020_asm3ComStatusError TRCM failure during ASM3 sensor initialization or main loop
- TRCM_a021 — Task Scheduler Error TRCM_a021_TaskSchedulerError If a task was not able to run at the appropriate time.
- TRCM_a022 — Task Init Error TRCM_a022_TaskInitError If a task failed to initialize.
- TRCM_a023 — Asm3 Ars Status X Error TRCM_a023_asm3ArsStatusXError TRCM failure during ASM3 sensor initialization or main loop
- TRCM_a024 — Asm3 Acc Status Error TRCM_a024_asm3AccStatusError TRCM failure during ASM3 sensor initialization or main loop
- TRCM_a025 — CHCAN Bus Faults TRCM_a025_CHCANBusFaults CH CAN Bus has faults
- TRCM_a026 — Airbag Asic Diagnostic Fault TRCM_a026_airbagAsicDiagnosticFault TRCM fault due to airbag ASICs diagnostic check failure
- TRCM_a027 — Airbag Asic Deployment Diagnostic Fault TRCM_a027_airbagAsicDeploymentDiagnosticFault TRCM fault due to airbag ASICs deployment triggering/diagnostic routine failure
- TRCM_a028 — Chassis Length Error TRCM_a028_chassisLengthError The Restraint Control Module (RCM) receives a message on the CH bus with an unexpected message length.
- TRCM_a030 — ECU Log Upload Request TRCM_a030_ECULogUploadRequest Triggers on board diagnostics service to upload log buffer.
- TRCM_a031 — UDS Active TRCM_a031_UDSActive A unified diagnostics services (UDS) request was made
- TRCM_a032 — Scroll Created TRCM_a032_ScrollCreated A scroll log session was created
- TRCM_a033 — Herc Log Created TRCM_a033_HercLogCreated A Hercules log was created
- TRCM_a034 — Ap Clip Trigger TRCM_a034_apClipTrigger Signal to indicate that a qualifying TRCM event occured, which warrants the triggering of an AP clip
- TRCM_a035 — Hv Disconnect Commanded TRCM_a035_hvDisconnectCommanded The Restraint Control Module (RCM) commanded disconnection of the high voltage battery. This alert indicates that the RCM detected a collision event requiring isolation of the high voltage system for safety reasons.
- TRCM_a036 — Crash Detected TRCM_a036_crashDetected Restraint Control Module (RCM) reported crash event detected. This alert indicates that the vehicle was involved in a collision that resulted in deployment of pyrotechnic safety devices.
- TRCM_a037 — Near Deploy TRCM_a037_nearDeploy Restraint Control Module (RCM) reported near deploy event detected. This alert indicates that the vehicle was involved in a collision that did not reach the threshold for pyrotechnic device deployment but was significant enough to warrant…
- TRCM_a038 — Ens1 Degraded TRCM_a038_ens1Degraded The Emergency Notification Signal (ENS) connected to the High Voltage Controller (HVC) is in a degraded state.
- TRCM_a039 — Ens2 Degraded TRCM_a039_ens2Degraded The Emergency Notification Signal (ENS) connected to E-Call is in a degraded state.
- TRCM_a040 — Task500us Overrun Debug TRCM_a040_task500usOverrunDebug Debug information for 500us task errors.
- TRCM_a041 — High CPU Load TRCM_a041_HighCPULoad CPU under heavy load.
- TRCM_a042 — High Stack Usage TRCM_a042_HighStackUsage High stack memory usage was detected
- TRCM_a043 — Task1ms Error TRCM_a043_Task1msError Debug information for 1ms task errors.
- TRCM_a044 — Task10ms Error TRCM_a044_Task10msError Debug information for 10ms task errors
- TRCM_a045 — Task100ms Error TRCM_a045_Task100msError Debug information for 100ms task errors.
- TRCM_a046 — Task1000ms Error TRCM_a046_Task1000msError Debug information for 1000ms task errors.
- TRCM_a047 — Vin Not Learned TRCM_a047_vinNotLearned Vehicle Identification Number (VIN) initial configuration is not complete. This alert indicates that the Restraint Control Module has not learned the VIN of the vehicle, which is required for proper system operation.
- TRCM_a048 — Vin Mismatch TRCM_a048_vinMismatch Vehicle Identification Number (VIN) stored does not match received from vehicle. This alert indicates a mismatch between the VIN stored in the Restraint Control Module and the VIN received from the vehicle gateway.