Skip to content

TRCM_a038 — Ens1 Degraded

Full alert identifier: TRCM_a038_ens1Degraded

Message shown in the car

Safety restraint system issue Service is required

Alert description

The Emergency Notification Signal (ENS) connected to the High Voltage Controller (HVC) is in a degraded state.

Potential impact

The High Voltage Pyro Disconnect may not operate as expected.

Set condition

There is an electrical condition with the ENS-1 line, such as a short circuit or disconnection.

Clear condition

The electrical condition is corrected.

Signals to check

These diagnostic fields are associated with TRCM_a038. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Driver Over Temperature TRCM_a038_driverOverTemperature —
Over Current TRCM_a038_overCurrent —
Stuck High TRCM_a038_stuckHigh —
Stuck Low Or Open Circuit TRCM_a038_stuckLowOrOpenCircuit —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of TRCM_a038.

Browse all TRCM alert codes