Front-right door vehicle controller alerts
Browse 145 VCDOORFR alert codes and open an entry for its description and recorded conditions.
VCDOORFR alert codes
Showing 101–145 of 145
- VCDOORFR_a280 — Latch Did Not Disarm VCDOORFR_a280_latchDidNotDisarm Latch should report disarmed during release
- VCDOORFR_a282 — Latch Unexpected Arm VCDOORFR_a282_latchUnexpectedArm Latch reported rearming while releasing
- VCDOORFR_a286 — Window Speed Invalid VCDOORFR_a286_windowSpeedInvalid Window speed is too fast or in the wrong direction.
- VCDOORFR_a310 — Mirror Fold Stall VCDOORFR_a310_mirrorFoldStall Mirror stalled unexpectedly while folding or unfolding
- VCDOORFR_a311 — Mirror Fold Debug VCDOORFR_a311_mirrorFoldDebug Mirror fold debug alert
- VCDOORFR_a316 — Mirror Premature Fold Stall VCDOORFR_a316_mirrorPrematureFoldStall A side-view mirror started a fold or unfold movement, but then stalled before finishing the movement. The mirror will attempt 1 retry to complete the movement.
- VCDOORFR_a320 — Window Report Cracked At Trim Clear VCDOORFR_a320_windowReportCrackedAtTrimClear Window position reported as cracked at trim clear position
- VCDOORFR_a321 — Window Rezeroed Debug VCDOORFR_a321_windowRezeroedDebug Window rezeroed from last calibration due to drift
- VCDOORFR_a323 — Mirror Calibrated VCDOORFR_a323_mirrorCalibrated Mirror has calibration parameters stored
- VCDOORFR_a324 — Mirror Heat Fault VCDOORFR_a324_mirrorHeatFault Mirror heat undercurrent detected, indicating mirror heating may be limited or unavailable
- VCDOORFR_a330 — Short Drop Failed VCDOORFR_a330_shortDropFailed Window glass did not short drop while opening the door.
- VCDOORFR_a336 — Window Drop Rev Thermal VCDOORFR_a336_windowDropRevThermal Window glass did not roll back up after closing the door.
- VCDOORFR_a373 — Window Sw Open Req In Dog Mode VCDOORFR_a373_windowSwOpenReqInDogMode Window switch open requests are ignored when Dog Mode is active to prevent pet escape
- VCDOORFR_a375 — Window Pinch Override Nudge VCDOORFR_a375_windowPinchOverrideNudge Two window pinch events occured within 30 seconds of each other
- VCDOORFR_a400 — Presenter Uncal VCDOORFR_a400_presenterUncal Door Presenter is not calibrated
- VCDOORFR_a401 — Presenter Unknown Body Position VCDOORFR_a401_presenterUnknownBodyPosition Door Presenter has not learned or does not know where the body of the vehicle is
- VCDOORFR_a402 — Presenter Unexpected Stop VCDOORFR_a402_presenterUnexpectedStop Door presenter has stopped for unexpected reasons.
- VCDOORFR_a403 — Presenter Rezero DBG VCDOORFR_a403_presenterRezeroDBG Presenter rezeroed from last calibration due to drift
- VCDOORFR_a404 — Presenter Excessive Soft Stall VCDOORFR_a404_presenterExcessiveSoftStall Presenter was in the soft stall state for much longer than expected
- VCDOORFR_a405 — Presenter High Stiction Duty Diff VCDOORFR_a405_presenterHighStictionDutyDiff Successive presenter stiction breaks had a high differenence in duty cycle
- VCDOORFR_a406 — Unexpected Present VCDOORFR_a406_unexpectedPresent Presenter presented from an unexpected door request
- VCDOORFR_a407 — Presenter Retracted From Timoeut VCDOORFR_a407_presenterRetractedFromTimoeut Presenter retracted because the door door angle did not increase past the retract request position for over 1 minute
- VCDOORFR_a408 — Door Angle Unexpected VCDOORFR_a408_doorAngleUnexpected The angle calculated from the door Inertial Measurement Unit (IMU) signal conflicts with the presenter position and latch state.
- VCDOORFR_a409 — Presenter Stuck Out VCDOORFR_a409_presenterStuckOut Door presenter is stuck presented even through there is a valid retract request
- VCDOORFR_a410 — Waiting For Soft Stall Timeout VCDOORFR_a410_waitingForSoftStallTimeout Presenter did not reach the soft stalling state within the allotted wait time.
- VCDOORFR_a411 — Presenter Disconnected VCDOORFR_a411_presenterDisconnected Lack of current and encoder ticks from the presenter indicates it is no longer connected to the controlller
- VCDOORFR_a412 — Presenter Body Find Failed VCDOORFR_a412_presenterBodyFindFailed Presenter failed to successfully set the body positon during the body find state
- VCDOORFR_a413 — Interior Release Failed VCDOORFR_a413_interiorReleaseFailed Door latch was released via the interior button, but the door did not transtion to an open state, instead it remained closed
- VCDOORFR_a414 — Undervoltage Self Test Failure VCDOORFR_a414_undervoltageSelfTestFailure The Door Vehicle Controller (VCDOOR) self-test did not pass, as a condition affecting a load on the VCDOOR was detected during the self-test.
- VCDOORFR_a415 — Undervoltage Self Test Stuck Off VCDOORFR_a415_undervoltageSelfTestStuckOff One or more loads did not turn on during the Door Vehicle Controller (VCDOOR) undervoltage self-test. Those loads will be inhibited from use while in Drive.
- VCDOORFR_a420 — Door Present Failed VCDOORFR_a420_doorPresentFailed An open was requested from the exterior button or mobile app but the door presenter did not present the door
- VCDOORFR_a421 — Presenter Soft Stall Pos Irrational VCDOORFR_a421_presenterSoftStallPosIrrational The presenter soft stalled at a position that is closer to the fully retracted position than expected
- VCDOORFR_a422 — Door Remote Open VCDOORFR_a422_doorRemoteOpen Door latch has been actuated due to a remote open request
- VCDOORFR_a423 — Door Remote Open Failed VCDOORFR_a423_doorRemoteOpenFailed A remote open was requested but the door latch stayed closed - the door seal is potentially frozen
- VCDOORFR_a424 — Door Angle Est Faulted VCDOORFR_a424_doorAngleEstFaulted The door angle position no longer makes sense indicating the calculations are faulty
- VCDOORFR_a425 — Door Presenter Abuse Event Detected VCDOORFR_a425_doorPresenterAbuseEventDetected The door presenter has determined that an abuse event has occurred
- VCDOORFR_a430 — Interior Release Switch Disabled Dbg VCDOORFR_a430_interiorReleaseSwitchDisabledDbg Developer Purposes only: The vehicle controller disabled the door switch.
- VCDOORFR_a431 — Interior Release Switch Volt Dbg VCDOORFR_a431_interiorReleaseSwitchVoltDbg Developer Purposes only: The vehicle controller received invalid values from the door switch, indicating the voltage is outside of the expected range.
- VCDOORFR_a470 — Side Mirror Heater Fault VCDOORFR_a470_sideMirrorHeaterFault The front door controller (VCDOORFL or VCDOORFR) detects that the side mirror glass heater current is not within the expected range.
- VCDOORFR_a482 — NCV77 XX Fault VCDOORFR_a482_NCV77XXFault The driver integrated circuit (IC) experiences a condition affecting the operation of the loads controlled by the device.
- VCDOORFR_a483 — Undervoltage Self Test Stuck On Debug VCDOORFR_a483_undervoltageSelfTestStuckOnDebug The Door Domain Undervoltage self-test did not pass, as a condition affecting a load on the Door Domain was detected during the self-test.
- VCDOORFR_a484 — Undervoltage Self Test Stuck On VCDOORFR_a484_undervoltageSelfTestStuckOn One or more loads did not turn off during the VCDOOR Undervoltage self-test.
- VCDOORFR_a490 — Vehicle Occupied On OTA Start VCDOORFR_a490_vehicleOccupiedOnOTAStart The passenger or driver seat was occupied when the OTA update started
- VCDOORFR_a500 — Interior Trim Connector Unplugged VCDOORFR_a500_interiorTrimConnectorUnplugged The interior door trim connector appears to be unplugged from the door controller based on the voltages from the interior door release button and window switch(es)
- VCDOORFR_a578 — RGB Light Fault VCDOORFR_a578_RGBLightFault A Red Green Blue (RGB) light error has been detected.