VCDOORFR_a310 — Mirror Fold Stall
Full alert identifier: VCDOORFR_a310_mirrorFoldStall
Alert description
Mirror stalled unexpectedly while folding or unfolding
Potential impact
Mirror might be halfway between folded and unfolded
Set condition
If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.
Clear condition
Successful mirror fold or unfold
Signals to check
These diagnostic fields are associated with VCDOORFR_a310. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Ambient Temperature
VCDOORFR_
|
degC |
Folding Direction
VCDOORFR_
|
— |
Mirror Fold Time
VCDOORFR_
|
ms |
Mirror Max Fold Current
VCDOORFR_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFR_a310.