Skip to content

VCDOORFR_a310 — Mirror Fold Stall

Full alert identifier: VCDOORFR_a310_mirrorFoldStall

Alert description

Mirror stalled unexpectedly while folding or unfolding

Potential impact

Mirror might be halfway between folded and unfolded

Set condition

If folding motor current exceeds 0.5A or decreases below 0.1A after 500ms from beginning of actuation. Or timeout from current state after 5 seconds.

Clear condition

Successful mirror fold or unfold

Signals to check

These diagnostic fields are associated with VCDOORFR_a310. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temperature VCDOORFR_a310_ambientTemperature
0
SNA
degC
Folding Direction VCDOORFR_a310_foldingDirection
0
FOLD
1
UNFOLD
—
Mirror Fold Time VCDOORFR_a310_mirrorFoldTime ms
Mirror Max Fold Current VCDOORFR_a310_mirrorMaxFoldCurrent A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFR_a310.

Browse all VCDOORFR alert codes