VCDOORFR_a402 — Presenter Unexpected Stop

Full alert identifier: VCDOORFR_a402_presenterUnexpectedStop

Alert description

Door presenter has stopped for unexpected reasons.

Potential impact

Door presenter may require calibration or replacement.

Set condition

Door presenter experiences an unexpected stop.

Clear condition

Door presenter moves again.

Signals to check

These diagnostic fields are associated with VCDOORFR_a402. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Ambient Temperature VCDOORFR_a402_ambientTemperature
0
SNA
degC
Presenter Current VCDOORFR_a402_presenterCurrent A
Presenter Position VCDOORFR_a402_presenterPosition mm
State When Triggered VCDOORFR_a402_stateWhenTriggered —
Stopping Condition VCDOORFR_a402_stoppingCondition
0
NONE
1
CURRENT STALL
2
CURRENT SPIKE
3
ENCODER STALL
4
STATE TIMEOUT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCDOORFR_a402.

Browse all VCDOORFR alert codes