Steering column control module alerts
Browse 22 SCCM alert codes and open an entry for its description and recorded conditions.
SCCM alert codes
Showing 1–22 of 22
- SCCM_a001 — Voltage High SCCM_a001_voltageHigh Alert for detecting if measured local input power supply is above max voltage range of 18V for 15 seconds.
- SCCM_a002 — Voltage Low SCCM_a002_voltageLow Alert for detecting if measured local input power supply is below min voltage range of 8V for 15 seconds
- SCCM_a003 — Angle Out Of Range SCCM_a003_angleOutOfRange Alert for detecting if the measured steering angle is out of +/- 492 degrees range.
- SCCM_a004 — Angle Speed Out Of Range SCCM_a004_angleSpeedOutOfRange Alert for detecting if the measured steering angle sensor speed is out of +/- 3000 degrees/second range.
- SCCM_a005 — Angle Not Plausible SCCM_a005_angleNotPlausible The steering angle sensor detected an implausible angle error. Steering may not operate as expected.
- SCCM_a006 — Angle Speed Not Plausible SCCM_a006_angleSpeedNotPlausible Alert for detecting an instantaneous angle speed plausibility error.
- SCCM_a007 — CAN Bus Off SCCM_a007_CANBusOff Steering Column Control Module (SCCM) detected Controller Area Network (CAN) Bus Off.
- SCCM_a008 — CANLV Power State LOC SCCM_a008_CANLVPowerState_LOC Steering Column Control Module (SCCM) is not receiving a low voltage power state from the front vehicle controller (VCFRONT).
- SCCM_a009 — Calibration Mismatch SCCM_a009_calibrationMismatch Alert for detecting if compared consistency of two stored zero calibration angle values does not match
- SCCM_a010 — Angle Trim Mismatch SCCM_a010_angleTrimMismatch Alert for detecting if compared consistency of two stored angle trim values do not match (trimming angle saved by Angle Trim Command)
- SCCM_a011 — Angle Hall Sensor Error SCCM_a011_angleHallSensorError Sensor chip 1 or 2 detects a condition affecting functionality. Steering may not operate as expected.
- SCCM_a012 — Spi Bit Errors SCCM_a012_spiBitErrors Bit errors are detected in the internal bus messages between microcontroller and Hall sensors. Steering may not operate as expected.
- SCCM_a013 — Watchdog Reset SCCM_a013_watchdogReset An internal control unit reset and a condition affecting functionality are detected. Steering may not operate as expected.
- SCCM_a014 — PLL Loss Of Lock SCCM_a014_PLLLossOfLock The lock of the phase-locked loop (PLL) is lost. Steering may not operate as expected.
- SCCM_a015 — Hardware Error SCCM_a015_hardwareError Steering Column Control Module (SCCM) steering stalk module hardware issue is detected.
- SCCM_a016 — Memory Error SCCM_a016_memoryError Steering Column Control Module (SCCM) detected a steering stalk module memory error.
- SCCM_a017 — Gear Angle Not Plausible SCCM_a017_gearAngleNotPlausible SCCM detected inplausible gear angle
- SCCM_a018 — ADC Calibration Error SCCM_a018_ADCCalibrationError The Analog-Digital Converter calibration reports an issue after powering up the Steering Column Control Module (SCCM). Steering may not operate as expected.
- SCCM_a019 — Chip Temp Out Of Range SCCM_a019_chipTempOutOfRange Alert for detecting if the chip junction temperature has exceeded 100 C
- SCCM_a020 — ADC Self Test Failed SCCM_a020_ADCSelfTestFailed Alert for detecting if Analog-Digital Converter periodical self-test has failed
- SCCM_a021 — Startup Test Failed SCCM_a021_startupTestFailed One or more startup tests has reported an issue. Steering may not operate as expected.
- SCCM_a022 — Runtime Test Failed SCCM_a022_runtimeTestFailed One or more runtime tests has reported an issue. Steering may not operate as expected.