Skip to content

SCCM_a019 — Chip Temp Out Of Range

Full alert identifier: SCCM_a019_chipTempOutOfRange

Alert description

Alert for detecting if the chip junction temperature has exceeded 100 C

Potential impact

Steering functionality may not operate as expected.

Set condition

SCCM detected chip junction temperature over 100 C

Clear condition

The alert shall be cleared if the chip temperature is below 100 C for 10 seconds.

Signals to check

These diagnostic fields are associated with SCCM_a019. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Chip Temperature SCCM_a019_ChipTemperature degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SCCM_a019.

Browse all SCCM alert codes