SCCM_a002 — Voltage Low

Full alert identifier: SCCM_a002_voltageLow

Alert description

Alert for detecting if measured local input power supply is below min voltage range of 8V for 15 seconds

Potential impact

Steering functionality may not operate as expected.

Set condition

Measured local input power supply is below min voltage range of 8V for 15 seconds

Clear condition

SCCM local voltage is 0.5V above maturation threshold for 1 seconds

Signals to check

These diagnostic fields are associated with SCCM_a002. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Voltage SCCM_a002_voltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of SCCM_a002.