High-voltage battery controller alerts
Browse 424 HVBATT alert codes and open an entry for its description and recorded conditions.
HVBATT alert codes
Showing 201–250 of 424
- HVBATT_a204 — Ls Shunt Under Temperature HVBATT_a204_LsShuntUnderTemperature Low-side shunt bar temperature is too low
- HVBATT_a205 — Ls Shunt Sense Current Mismatch HVBATT_a205_LsShuntSenseCurrentMismatch Low-side shunt active sense and passive sense readings are not in agreement
- HVBATT_a206 — Ls Shunt Contactor Test Invalid HVBATT_a206_LsShuntContactorTestInvalid Low-side shunt active sense current reading deviates from zero when contactors are open
- HVBATT_a207 — Hs Shunt Disconnected HVBATT_a207_HsShuntDisconnected High-side shunt detects shunt connector as disconnected
- HVBATT_a208 — Hs Shunt Under Temperature HVBATT_a208_HsShuntUnderTemperature High-side shunt bar temperature is too low
- HVBATT_a209 — Hs Shunt Sense Current Mismatch HVBATT_a209_HsShuntSenseCurrentMismatch High-side shunt active sense and passive sense readings are not in agreement
- HVBATT_a210 — Hs Shunt Contactor Test Invalid HVBATT_a210_HsShuntContactorTestInvalid High-side shunt active sense current reading deviates from zero when contactors are open
- HVBATT_a211 — Cp Mismatch Fault HVBATT_a211_CpMismatchFault Warns if the gateway reports a ChargePort (CP) version mismatch
- HVBATT_a212 — Charge Aborted HVBATT_a212_ChargeAborted The active charging session has been aborted
- HVBATT_a213 — Dcdc Support Required When Leaving Suppor HVBATT_a213_DcdcSupportRequiredWhenLeavingSuppor HVBATT was held in a support state due to DCDC support being required.
- HVBATT_a214 — Charge Emergency Shutdown HVBATT_a214_ChargeEmergencyShutdown The active charging session has been shut down in an emergency
- HVBATT_a215 — Charge Ext Iso Check Failed HVBATT_a215_ChargeExtIsoCheckFailed The required external isolation check for charging failed
- HVBATT_a216 — Charge Faulted HVBATT_a216_ChargeFaulted The active charging session has faulted
- HVBATT_a217 — Cp Emergency Shutdown Requested HVBATT_a217_CpEmergencyShutdownRequested The Charge Port has requested an emergency shut down of the current charge session
- HVBATT_a218 — Evse Disable Timeout HVBATT_a218_EvseDisableTimeout The EVSE has failed to disable within the expected timeout
- HVBATT_a219 — Evse Enable Timeout HVBATT_a219_EvseEnableTimeout The EVSE has failed to initalize while attempting to pre-charge the Fast-Charge (FC) Link
- HVBATT_a220 — Fc Link Not Allowed To Energize HVBATT_a220_FcLinkNotAllowedToEnergize HVBATT has determined that the conditions for pre-charging the FC link are not met
- HVBATT_a221 — Pcs Emergency Shutdown Requested HVBATT_a221_PcsEmergencyShutdownRequested The PCS has requested an emergency shut down of the current charge session
- HVBATT_a222 — Acjb Hw Config Mismatch HVBATT_a222_AcjbHwConfigMismatch The battery management system (BMS) detects that the AC junction box (ACJB) config block does not match the ACJB connected to the BMS.
- HVBATT_a223 — Cp Mia HVBATT_a223_CpMia HVBATT's controller core is not receiving expected messages from the Charge Port on the HVS CAN bus.
- HVBATT_a224 — Vcleft Mia HVBATT_a224_VcleftMia HVBATT's controller core is not receiving expected messages from VCLEFT on the BP CAN bus.
- HVBATT_a225 — Di Mia HVBATT_a225_DiMia HVBATT's controller core is not receiving expected messages from the Drive Inverter on the BP CAN bus.
- HVBATT_a226 — Pcs Mia HVBATT_a226_PcsMia HVBATT's controller core is not receiving expected messages from the PCS on the HVS CAN bus.
- HVBATT_a227 — Gtw Mia HVBATT_a227_GtwMia HVBATT's controller core is not receiving expected messages from the Gateway on the BP CAN bus.
- HVBATT_a228 — Ui Mia HVBATT_a228_UiMia HVBATT's controller core is not receiving expected messages from the UI on the BP CAN bus.
- HVBATT_a229 — Pack Module Id Mismatch HVBATT_a229_PackModuleIdMismatch The module IDs do not match the pack type set by the config block.
- HVBATT_a230 — Charge Hv Fault HVBATT_a230_ChargeHvFault HVBATT exited charge due to a HV system fault.
- HVBATT_a231 — Charge Hv Graceful Fault HVBATT_a231_ChargeHvGracefulFault HVBATT initiated a graceful exit from charge due to a HV system fault.
- HVBATT_a232 — Drive Hv Fault HVBATT_a232_DriveHvFault HVBATT exited drive due to a HV system fault.
- HVBATT_a233 — Drive Hv Graceful Fault HVBATT_a233_DriveHvGracefulFault HVBATT initiated a graceful exit from drive due to a HV system fault.
- HVBATT_a234 — Support Hv Fault HVBATT_a234_SupportHvFault HVBATT exited support due to a HV system fault.
- HVBATT_a235 — Hv Up Dropped Gpo Took Too Long HVBATT_a235_HvUpDroppedGpoTookTooLong HVBATT dropped out of a state of HV UP because a graceful power off (GPO) took too long
- HVBATT_a236 — Cp Asserted Fault Line HVBATT_a236_CpAssertedFaultLine The battery management system (BMS) has detected that the Charge Port (CP) fault line is set.
- HVBATT_a237 — Bms Asserted Cp Fault Line HVBATT_a237_BmsAssertedCpFaultLine The battery management system (BMS) has asserted the Charge Port (CP) fault line.
- HVBATT_a238 — Hs Flyback Under Voltage HVBATT_a238_HsFlybackUnderVoltage The High Voltage Battery (HVBATT) detects the high-side (HS) flyback output voltage is below the operational threshold.
- HVBATT_a239 — Ls Flyback Under Voltage HVBATT_a239_LsFlybackUnderVoltage The High Voltage Battery (HVBATT) detects the low-side (LS) flyback output voltage is below the operational threshold.
- HVBATT_a240 — Energy Reserve Discharged HVBATT_a240_EnergyReserveDischarged Energy reserve voltage supply is below minimum voltage threshold
- HVBATT_a241 — Bp1 Pack Voltage Mismatch Fault HVBATT_a241_Bp1PackVoltageMismatchFault HVBATT detects that the sum of brick voltages deviates from measured pack voltage.
- HVBATT_a242 — Bp2 Pack Voltage Mismatch Fault HVBATT_a242_Bp2PackVoltageMismatchFault HVBATT detects that the sum of brick voltages deviates from measured pack voltage.
- HVBATT_a243 — Standby Supply Unavailable HVBATT_a243_StandbySupplyUnavailable The standby supply is unable to activate because no eligible power sources are available.
- HVBATT_a244 — Standby Supply Stuck On HVBATT_a244_StandbySupplyStuckOn The High Voltage Battery (HVBATT) detects the standby supply is stuck in the on state.
- HVBATT_a245 — Standby Supply Stuck Off HVBATT_a245_StandbySupplyStuckOff The High Voltage Battery (HVBATT) detects the standby supply is stuck in the OFF state.
- HVBATT_a246 — Bp1 Passive Pyro Duty Setpoint Invalid HVBATT_a246_Bp1PassivePyroDutySetpointInvalid The configured battery pack 1 passive pyro setpoint is invalid
- HVBATT_a247 — Bp2 Passive Pyro Duty Setpoint Invalid HVBATT_a247_Bp2PassivePyroDutySetpointInvalid The configured battery pack 2 passive pyro setpoint is invalid
- HVBATT_a248 — Acjb Cp Line Relay Welded HVBATT_a248_AcjbCpLineRelayWelded The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) line relay has welded.
- HVBATT_a249 — Acjb Cp Neutral Relay Welded HVBATT_a249_AcjbCpNeutralRelayWelded The battery management system (BMS) has detected that the AC Junction Box (ACJB) Charge Port (CP) neutral relay has welded.
- HVBATT_a250 — Hv Up Dropped In Support HVBATT_a250_HvUpDroppedInSupport HVBATT dropped out of a state of HV UP while in Support mode.
- HVBATT_a251 — Hv Up Dropped In Drive HVBATT_a251_HvUpDroppedInDrive HVBATT dropped out of a state of HV UP while in Drive mode.
- HVBATT_a252 — Hv Up Dropped In Charge HVBATT_a252_HvUpDroppedInCharge HVBATT dropped out of a state of HV UP while in Charge mode.
- HVBATT_a253 — Hv Up Dropped In Test HVBATT_a253_HvUpDroppedInTest HVBATT dropped out of a state of HV UP while in Test mode.