Alert description
Low-side shunt active sense and passive sense readings are not in agreement
Potential impact
Low-side sub pack may not come online
Set condition
Low-side shunt active sense and passive sense readings have a delta outside of the acceptable margin
Clear condition
Low-side shunt active sense and passive sense readings have a delta within the acceptable margin
Signals to check
These diagnostic fields are associated with HVBATT_a205. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Shunt Current
HVBATT_
|
A |
Shunt Passive Current
HVBATT_
|
A |