HVBATT_a495 — Hv Mon Ls Shunt Over Current
Full alert identifier: HVBATT_a495_HvMonLsShuntOverCurrent
Alert description
Warns if the low-side shunt current (discharge or charge) is above max current limit.
Potential impact
The pyro disconnect will blow
Set condition
The low-side shunt current (discharge or charge) is above max current limit.
Clear condition
The low-side shunt current (discharge or charge) is below max current limit.
Signals to check
These diagnostic fields are associated with HVBATT_a495. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Max Current Allowed
HVBATT_
|
A |
Shunt Current
HVBATT_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a495.