HVBATT_a241 — Bp1 Pack Voltage Mismatch Fault

Full alert identifier: HVBATT_a241_Bp1PackVoltageMismatchFault

Alert description

HVBATT detects that the sum of brick voltages deviates from measured pack voltage.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

HVBATT detects that the sum of brick voltages in BP1 deviates from pack voltage by more than 5 percent.

Clear condition

HVBATT detects that the sum of brick voltages in BP1 is within 5 percent of the measured pack voltage.

Signals to check

These diagnostic fields are associated with HVBATT_a241. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Subpack Voltage By Adc HVBATT_a241_subpackVoltageByAdc V
Subpack Voltage By Sum Of Bricks HVBATT_a241_subpackVoltageBySumOfBricks V