HVBATT_a242 — Bp2 Pack Voltage Mismatch Fault

Full alert identifier: HVBATT_a242_Bp2PackVoltageMismatchFault

Alert description

HVBATT detects that the sum of brick voltages deviates from measured pack voltage.

Potential impact

Inability to charge, drive, or support the low voltage (LV) system

Set condition

HVBATT detects that the sum of brick voltages in BP2 deviates from pack voltage by more than 5 percent.

Clear condition

HVBATT detects that the sum of brick voltages in BP2 is within 5 percent of the measured pack voltage.

Signals to check

These diagnostic fields are associated with HVBATT_a242. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Subpack Voltage By Adc HVBATT_a242_subpackVoltageByAdc V
Subpack Voltage By Sum Of Bricks HVBATT_a242_subpackVoltageBySumOfBricks V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a242.