HVBATT_a075 — Bp2 Brick Under Voltage Fault
Full alert identifier: HVBATT_a075_Bp2BrickUnderVoltageFault
Alert description
A battery pack 2 brick voltage is below the under voltage fault limit
Potential impact
Inability to enter drive or support the low voltage (LV) system
Set condition
A battery pack 2 brick voltage is below the under voltage fault limit for X duration (in seconds)
Clear condition
All battery pack 2 brick voltages are above the under voltage fault limit
Signals to check
These diagnostic fields are associated with HVBATT_a075. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Brick Id
HVBATT_
|
— |
Brick Voltage Max
HVBATT_
|
V |
Brick Voltage Min
HVBATT_
|
V |
Pack Current
HVBATT_
|
A |
Soc Min
HVBATT_
|
% |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a075.