Skip to content

HVBATT_a075 — Bp2 Brick Under Voltage Fault

Full alert identifier: HVBATT_a075_Bp2BrickUnderVoltageFault

Alert description

A battery pack 2 brick voltage is below the under voltage fault limit

Potential impact

Inability to enter drive or support the low voltage (LV) system

Set condition

A battery pack 2 brick voltage is below the under voltage fault limit for X duration (in seconds)

Clear condition

All battery pack 2 brick voltages are above the under voltage fault limit

Signals to check

These diagnostic fields are associated with HVBATT_a075. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Brick Id HVBATT_a075_brickId —
Brick Voltage Max HVBATT_a075_brickVoltageMax V
Brick Voltage Min HVBATT_a075_brickVoltageMin V
Pack Current HVBATT_a075_packCurrent A
Soc Min HVBATT_a075_socMin %

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of HVBATT_a075.

Browse all HVBATT alert codes