Right Etherloop gateway (Sitara 3) alerts
Browse 143 EGGRIGHT3 alert codes and open an entry for its description and recorded conditions.
EGGRIGHT3 alert codes
Showing 101–143 of 143
- EGGRIGHT3_a355 — Coolant Sys Lockout EGGRIGHT3_a355_coolantSysLockout The vehicle controller detects the vehicle is not factory gated or the coolant is not filled, causing the coolant pumps to turn off and the coolant valve to be in Series or No Bypass mode.
- EGGRIGHT3_a356 — Refrig Sys Lockout EGGRIGHT3_a356_refrigSysLockout The vehicle controller detects the vehicle is not factory gated or the refrigerant is not filled, causing the compressor to be unavailable and the refrigerant valves (solenoid or electronic expansion valves (EXV)) to remain open.
- EGGRIGHT3_a367 — Discharge Routine Entered EGGRIGHT3_a367_dischargeRoutineEntered HV Battery Discharge routine entered, expect the HV Battery Discharge routine to run
- EGGRIGHT3_a368 — Discharge Routine Exited EGGRIGHT3_a368_dischargeRoutineExited HV Battery Discharge routine exited, the HV Battery Discharge will not run until reset conditions are met.
- EGGRIGHT3_a369 — Reduced Power Discharge EGGRIGHT3_a369_reducedPowerDischarge HV Battery Discharge routine is running with reduced power, the battery will discharge at a lower rate than expected.
- EGGRIGHT3_a390 — Heat Pump Mode Convergence EGGRIGHT3_a390_heatPumpModeConvergence The Heat Pump mode selection cycle didn't converge for a specific load type.
- EGGRIGHT3_a394 — Pressure Sensor Check Fault EGGRIGHT3_a394_pressureSensorCheckFault A condition affecting functionality of one or more refrigerant pressure sensors is detected, which may affect compressor functionality and HVAC performance.
- EGGRIGHT3_a395 — Pressure Sensor Check Inconclusive EGGRIGHT3_a395_pressureSensorCheckInconclusive Refrigerant pressure sensor check did not pass or fail
- EGGRIGHT3_a397 — Temperature Sensor Check Fault EGGRIGHT3_a397_temperatureSensorCheckFault A condition affecting functionality of one or more refrigerant temperature sensors is detected, which may affect compressor functionality and HVAC performance.
- EGGRIGHT3_a398 — Temp Sensor Check Inconclusive EGGRIGHT3_a398_tempSensorCheckInconclusive Refrigerant temperature sensor check did not pass or fail
- EGGRIGHT3_a446 — Cabin HVAC Unavailable Context EGGRIGHT3_a446_cabinHVACUnavailableContext Condition(s) affecting the thermal management system have reduced cabin heating and/or cooling performance or made cabin heating and/or cooling unavailable.
- EGGRIGHT3_a447 — Cabin HVAC Unavailable EGGRIGHT3_a447_cabinHVACUnavailable The vehicle controller detects a condition(s) affecting the Thermal Management System that prevents it from performing as designed.
- EGGRIGHT3_a451 — Refrigerant Not Commissioned EGGRIGHT3_a451_refrigerantNotCommissioned The refrigerant system has not been commissioned or has been decommissioned by the Thermal Fill Drain service routine.
- EGGRIGHT3_a452 — Discharge Pres Sens Intermittent EGGRIGHT3_a452_dischargePresSensIntermittent The refrigerant discharge pressure sensor signal is intermittent.
- EGGRIGHT3_a453 — Discharge Temp Sens Intermittent EGGRIGHT3_a453_dischargeTempSensIntermittent The refrigerant discharge temperature sensor signal is intermittent.
- EGGRIGHT3_a454 — Suction Pres Sens Intermittent EGGRIGHT3_a454_suctionPresSensIntermittent The refrigerant suction pressure sensor signal is intermittent.
- EGGRIGHT3_a455 — Suction Temp Sens Intermittent EGGRIGHT3_a455_suctionTempSensIntermittent The refrigerant suction temperature sensor signal is intermittent.
- EGGRIGHT3_a456 — Liquid Pres Sens Intermittent EGGRIGHT3_a456_liquidPresSensIntermittent The refrigerant liquid pressure sensor signal is intermittent.
- EGGRIGHT3_a457 — Liquid Temp Sens Intermittent EGGRIGHT3_a457_liquidTempSensIntermittent The refrigerant liquid temperature sensor signal is intermittent.
- EGGRIGHT3_a458 — Grossly Low Refrigerant EGGRIGHT3_a458_grosslyLowRefrigerant Refrigerant pressures have been detected as too low for the current temperature
- EGGRIGHT3_a459 — Thermal Fill And Drive EGGRIGHT3_a459_thermalFillAndDrive The vehicle controller detects that the Thermal Fill Drain service routine is being run while the vehicle is in Drive.
- EGGRIGHT3_a460 — Hard Isentropic Td Failed EGGRIGHT3_a460_hardIsentropicTdFailed The vehicle controller detects the isentropic check for the refrigerant discharge temperature (TD) is unsuccessful, indicating the A/C compressor mass flow rate is below the expected level.
- EGGRIGHT3_a464 — High Flow Index High Subcool Flagged EGGRIGHT3_a464_highFlowIndexHighSubcoolFlagged The vehicle controller detects a discrepancy in the estimated refrigerant flow rates between the A/C compressor and recirculation electronic expansion valve (EXV) as the estimated refrigerant flow index is higher than expected while the su…
- EGGRIGHT3_a465 — Low Flow Index High Subcool Flagged EGGRIGHT3_a465_lowFlowIndexHighSubcoolFlagged The flow index value is low at high subcool. The refrigerant flow rate through the electronic expansion valves (EXV) is not meeting the expected value when compared to the compressor refrigerant flow rate.
- EGGRIGHT3_a466 — High Flow Index Low Subcool Flagged EGGRIGHT3_a466_highFlowIndexLowSubcoolFlagged The vehicle controller detects a discrepancy in the estimated refrigerant flow rates between the A/C compressor and recirculation electronic expansion valve (EXV) as the estimated refrigerant flow index is higher than expected while the su…
- EGGRIGHT3_a467 — Low Power Index Flagged EGGRIGHT3_a467_lowPowerIndexFlagged The vehicle controller detects the actual A/C compressor power is lower than expected.
- EGGRIGHT3_a468 — High Power Index Flagged EGGRIGHT3_a468_highPowerIndexFlagged Actual compressor power is lower than expected, as measured by the compressor power index.
- EGGRIGHT3_a469 — Prv Pop Detected EGGRIGHT3_a469_prvPopDetected The compressor or discharge lines may have a possible blockage
- EGGRIGHT3_a470 — Implausible Pd Pl Detected EGGRIGHT3_a470_implausiblePdPlDetected Difference between the discharge pressure and liquid pressure (Pd-Pl) increased. Discharge lines or Liquid Cooled Condenser (LCC) may be blocked.
- EGGRIGHT3_a489 — Valve Stuck Flagged EGGRIGHT3_a489_ValveStuckFlagged EXV/SOV opening is different from commanded
- EGGRIGHT3_a499 — Load Shed Pump Flow Request EGGRIGHT3_a499_loadShedPumpFlowRequest Vehicle is running pumps during loadshed due to the HVBMS being hot
- EGGRIGHT3_a504 — Air In Refrigerant Detected EGGRIGHT3_a504_airInRefrigerantDetected Low flow index has been detected at high subcool at steady state or suction superheat is found to be abnormally low, which indicates that air bubbles are circulating in the refrigerant system.
- EGGRIGHT3_a531 — Low Power Index Flagged User Facing EGGRIGHT3_a531_lowPowerIndexFlaggedUserFacing The compressor power index is lower than expected, which typically indicates a condition affecting the compressor. This can also indicate a condition affecting the discharge or suction pressure sensors. The compressor power index measures…
- EGGRIGHT3_a542 — Refrigerant Reclaim EGGRIGHT3_a542_refrigerantReclaim The vehicle controller detected that the refrigerant was being reclaimed. This alert is for logging only.
- EGGRIGHT3_a543 — Compressor Low Flow Delivery Detected EGGRIGHT3_a543_compressorLowFlowDeliveryDetected The vehicle controller detected that the compressor delivered much less refrigerant flow than nominal and discharge temperature was abnormally high.
- EGGRIGHT3_a544 — Radiator Steam Detected EGGRIGHT3_a544_radiatorSteamDetected The coolant system detects the current ambient and vehicle conditions are likely to cause water vapor to steam from the radiator.
- EGGRIGHT3_a560 — Compressor High Superheat EGGRIGHT3_a560_compressorHighSuperheat The vehicle controller detects a refrigerant condition, such as low refrigerant or a blocked refrigerator filter, which may prevent the A/C compressor from operating as expected due to high suction superheat if no other heat pump modes are…
- EGGRIGHT3_a569 — Pump Air Lock EGGRIGHT3_a569_pumpAirLock The VCSUPER and EGGRIGHT3 controller detects an air lock in the pump due to smaller than expected pump current values
- EGGRIGHT3_a570 — Coolant Air Purge Incomplete EGGRIGHT3_a570_coolantAirPurgeIncomplete The Supermanifold Vehicle Controller (VCSUPER) and Etherloop Generalized Gateway Right (EGGRIGHT3) controller area network (CAN) node detects an incomplete coolant air purge due to abnormal pump current profile or terminated purge routine.
- EGGRIGHT3_a571 — Pump Detects Low Coolant Flow EGGRIGHT3_a571_pumpDetectsLowCoolantFlow The Etherloop Generalized Gateway Right (EGGRIGHT3) controller area network (CAN) node detects low coolant flow based on the pump's flow model using the phase current.
- EGGRIGHT3_a606 — Chiller Batt Heating Exit EGGRIGHT3_a606_chillerBattHeatingExit The refrigerant system stopped chiller battery heating session
- EGGRIGHT3_a611 — Poor Radiator Heat Rejection EGGRIGHT3_a611_poorRadiatorHeatRejection Powertrain inlet coolant temperature is higher than the nominal expected value under similar operating conditions.
- EGGRIGHT3_a618 — Cabin Cooling Capacity Limited EGGRIGHT3_a618_cabinCoolingCapacityLimited The thermal hardware is operating at its expected nominal air temperature under the given conditions; however, the system's capacity limitations prevent it from reaching the desired target temperature.