- EGGRIGHT3_a124 — HVBATTCON MIA EGGRIGHT3_a124_HVBATTCON_MIA One or more of the messages the vehicle controller receives periodically from the High Voltage Battery Management System Controller (HVBATTCON) is not received, indicating the HVBATTCON may be unavailable (MIA).
- EGGRIGHT3_a125 — EGGRIGHT1 MIA EGGRIGHT3_a125_EGGRIGHT1_MIA One or more of the expected CAN messages from the Etherloop Generalized Gateway Right (Core 1) were not received, indicating the EGGRIGHT1 ECU may be unavailable (MIA).
- EGGRIGHT3_a129 — CMPT MIA EGGRIGHT3_a129_CMPT_MIA One or more of the messages the vehicle controller receives periodically from the heat pump system compressor (CMPT) electronic control unit (ECU) is not received, indicating the CMPT ECU may be unavailable (MIA).
- EGGRIGHT3_a131 — PCSCOMMON MIA EGGRIGHT3_a131_PCSCOMMON_MIA One or more of the messages the vehicle controller receives periodically from the power conversion system common interface (PCSCOMMON) electronic control unit (ECU) is not received, indicating the PCSCOMMON ECU may be unavailable (MIA).
- EGGRIGHT3_a133 — DI MIA EGGRIGHT3_a133_DI_MIA One or more of the messages the vehicle controller receives periodically from the front drive inverter (DIF) electronic control unit (ECU) is not received, indicating the DIF ECU may be unavailable (MIA).
- EGGRIGHT3_a160 — Compressor Inhibited EGGRIGHT3_a160_compressorInhibited The vehicle controller detects a condition affecting the refrigerant compressor, which may prevent the refrigerant compressor from running as expected. This alert is set in addition to one or more alert(s) indicating a specific condition a…
- EGGRIGHT3_a161 — Compressor Self Fault EGGRIGHT3_a161_compressorSelfFault The vehicle controller detects the refrigerant compressor is reporting an internal condition.
- EGGRIGHT3_a162 — Compressor Inhibited Context EGGRIGHT3_a162_compressorInhibitedContext Refrigerant compressor operation is inhibited. Cabin cooling (air conditioning) will be disabled. Powertrain performance may be limited. Other alerts relevant to the specific condition should be present, including refrigDischg (refrigerant…
- EGGRIGHT3_a163 — Compressor Disabled FSR EGGRIGHT3_a163_compressorDisabledFSR The High Voltage (HV) compressor is unavailable after a repeated inability to start is detected, to avoid a condition affecting electrical isolation.
- EGGRIGHT3_a165 — VCSUPER MIA EGGRIGHT3_a165_VCSUPER_MIA One or more of the messages the vehicle controller receives periodically from the Thermal Supermanifold Vehicle Controller (VCSUPER) is not received, indicating the VCSUPER may be unavailable (MIA).
- EGGRIGHT3_a167 — VCDOORFR MIA EGGRIGHT3_a167_VCDOORFR_MIA One or more of the messages the vehicle controller receives periodically from the front right door controller (VCDOORFR) is not received, indicating the VCDOORFR may be unavailable (MIA).
- EGGRIGHT3_a168 — VCDOORRL MIA EGGRIGHT3_a168_VCDOORRL_MIA One or more of the messages the vehicle controller receives periodically from the rear left door controller (VCDOORRL) is not received, indicating the VCDOORRL may be unavailable (MIA).
- EGGRIGHT3_a170 — VCDOORFL MIA EGGRIGHT3_a170_VCDOORFL_MIA One or more of the messages the vehicle controller receives periodically from the front left door controller (VCDOORFL) is not received, indicating the VCDOORFL may be unavailable (MIA).
- EGGRIGHT3_a171 — VCDOORRR MIA EGGRIGHT3_a171_VCDOORRR_MIA One or more of the messages the vehicle controller receives periodically from the rear right door controller (VCDOORRR) is not received, indicating the VCDOORRR may be unavailable (MIA).
- EGGRIGHT3_a176 — EGGRIGHT MIA EGGRIGHT3_a176_EGGRIGHT_MIA One or more of the expected CAN messages from the Etherloop Generalized Gateway Right (Core 0) were not received, indicating the EGGRIGHT ECU may be unavailable (MIA).
- EGGRIGHT3_a178 — Comp Liquid Pump Out EGGRIGHT3_a178_compLiquidPumpOut The refrigerant system has potentially detected liquid in the compressor and may attempt to perform liquid pump out routine
- EGGRIGHT3_a184 — Cabin Cooling Performance Abnormal EGGRIGHT3_a184_cabinCoolingPerformanceAbnormal VCFRONT detected that the evaporator temperature is missing target and higher than expectation.
- EGGRIGHT3_a200 — Airwave Right Vertical Unavailable EGGRIGHT3_a200_airwaveRightVerticalUnavailable A condition affecting right vertical airwave cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a201 — Airwave Right Lateral Unavailable EGGRIGHT3_a201_airwaveRightLateralUnavailable A condition affecting right lateral airwave cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a202 — Airwave Left Vertical Unavailable EGGRIGHT3_a202_airwaveLeftVerticalUnavailable A condition affecting left vertical airwave cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a203 — Airwave Left Lateral Unavailable EGGRIGHT3_a203_airwaveLeftLateralUnavailable A condition affecting left lateral airwave cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a204 — Right Panel Actuator Unavailable EGGRIGHT3_a204_rightPanelActuatorUnavailable A condition affecting right panel cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a205 — Left Panel Actuator Unavailable EGGRIGHT3_a205_leftPanelActuatorUnavailable A condition affecting left panel cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a206 — Lower Mode Actuator Unavailable EGGRIGHT3_a206_lowerModeActuatorUnavailable A condition affecting lower mode cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a207 — Defrost Actuator Unavailable EGGRIGHT3_a207_defrostActuatorUnavailable A condition affecting defrost cabin HVAC actuator functionality has been detected.
- EGGRIGHT3_a208 — Intake Fresh Actuator Unavailable EGGRIGHT3_a208_intakeFreshActuatorUnavailable A condition affecting fresh intake HVAC actuator functionality has been detected.
- EGGRIGHT3_a209 — Intake Recirc Actuator Unavailable EGGRIGHT3_a209_intakeRecircActuatorUnavailable A condition affecting recirc intake HVAC actuator functionality has been detected.
- EGGRIGHT3_a210 — Suction Bypass Actuator Unavailable EGGRIGHT3_a210_suctionBypassActuatorUnavailable A condition affecting suction bypass HVAC actuator functionality has been detected.
- EGGRIGHT3_a211 — Right Panel Actuator Warning EGGRIGHT3_a211_rightPanelActuatorWarning A potential condition affecting right panel HVAC actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a212 — Left Panel Actuator Warning EGGRIGHT3_a212_leftPanelActuatorWarning A potential condition affecting left panel HVAC actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a213 — Lower Mode Actuator Warning EGGRIGHT3_a213_lowerModeActuatorWarning A potential condition affecting lower mode HVAC actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a214 — Defrost Actuator Warning EGGRIGHT3_a214_defrostActuatorWarning A potential condition affecting defrost actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a215 — Intake Fresh Actuator Warning EGGRIGHT3_a215_intakeFreshActuatorWarning A potential condition affecting fresh intake actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a216 — Intake Recirc Actuator Warning EGGRIGHT3_a216_intakeRecircActuatorWarning A potential condition affecting recirculation (recirc) intake actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a217 — Suction Bypass Actuator Warning EGGRIGHT3_a217_suctionBypassActuatorWarning A potential condition affecting suction bypass actuator functionality has been detected. Either the actuator is dithering (moving back and forth) or stalled.
- EGGRIGHT3_a218 — I2C Fault EGGRIGHT3_a218_I2CFault Indicates there was a fault reported on an I2C bus.
- EGGRIGHT3_a222 — Abort Fault EGGRIGHT3_a222_abortFault Indicates there was a data abort fault reported on the ECU.
- EGGRIGHT3_a223 — Abort Fault Ext EGGRIGHT3_a223_abortFaultExt Indicates there was a data abort fault reported on the ECU.
- EGGRIGHT3_a224 — Ahb Write Fault EGGRIGHT3_a224_ahbWriteFault Indicates there was a fault reported on an AHB bus due to attempted write on a protected region.
- EGGRIGHT3_a225 — Airwave Right Vertical Drift EGGRIGHT3_a225_airwaveRightVerticalDrift Right vertical hvac actuator has drifted. The actuator stalled during a bound check in either the positive or negative direction
- EGGRIGHT3_a226 — Airwave Right Lateral Drift EGGRIGHT3_a226_airwaveRightLateralDrift Right lateral hvac actuator has drifted. The actuator stalled during a bound check in either the positive or negative direction
- EGGRIGHT3_a227 — Airwave Left Vertical Drift EGGRIGHT3_a227_airwaveLeftVerticalDrift Left vertical hvac actuator has drifted. The actuator stalled during a bound check in either the positive or negative direction
- EGGRIGHT3_a228 — Airwave Left Lateral Drift EGGRIGHT3_a228_airwaveLeftLateralDrift Left lateral hvac actuator has drifted. The actuator stalled during a bound check in either the positive or negative direction
- EGGRIGHT3_a231 — ADSP MIA EGGRIGHT3_a231_ADSP_MIA One or more expected Controller Area Network (CAN) messages from the Audio Digital Signal Processor (ADSP) electronic control unit (ECU) was not received. ADSP data from accelerometers may be unavailable.
- EGGRIGHT3_a232 — Low Side Controller High Fdbk EGGRIGHT3_a232_lowSideControllerHighFdbk Low side exv feedback controller has very high feedback value when low side is implementing super control
- EGGRIGHT3_a235 — Pt Temp Sns Irrational EGGRIGHT3_a235_ptTempSnsIrrational The vehicle controller detects the powertrain coolant temperature sensor is reporting an incorrect value.
- EGGRIGHT3_a236 — Bat Temp Sns Irrational EGGRIGHT3_a236_batTempSnsIrrational The vehicle controller detects the battery coolant temperature sensor is reporting an incorrect value.
- EGGRIGHT3_a240 — Low Side Compromised EGGRIGHT3_a240_lowSideCompromised Refrigerant compressor experienced low suction pressure, disabling certain heat pump modes indicated by the context data
- EGGRIGHT3_a249 — Coolant Valve Bad Mode EGGRIGHT3_a249_coolantValveBadMode The vehicle controller detects the coolant valve actuator is clocked incorrectly on the coolant valve.
- EGGRIGHT3_a340 — Coolant Flow Compromised EGGRIGHT3_a340_coolantFlowCompromised Coolant flow is compromised and not flowing to components as expected.