EGGRIGHT3_a160 — Compressor Inhibited
Full alert identifier: EGGRIGHT3_a160_compressorInhibited
Alert description
The vehicle controller detects a condition affecting the refrigerant compressor, which may prevent the refrigerant compressor from running as expected. This alert is set in addition to one or more alert(s) indicating a specific condition affecting refrigerant compressor functionality.
Potential impact
Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.
Set condition
At least one additional alert is present indicating a condition affecting refrigerant compressor functionality. Alert log signal data should provide more information on the specific condition(s) detected.
Clear condition
Additional alert(s) indicating a condition affecting refrigerant compressor functionality clear.
Signals to check
These diagnostic fields are associated with EGGRIGHT3_a160. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Compressor Rpm
EGGRIGHT3_
|
RPM |
Fault Sns Ambient Temp
EGGRIGHT3_
|
— |
Fault Sns Disch Press
EGGRIGHT3_
|
— |
Fault Sns Disch Temp
EGGRIGHT3_
|
— |
Fault Sns Suct Press
EGGRIGHT3_
|
— |
Fault Sns Suct Temp
EGGRIGHT3_
|
— |
Fault Valve EXV
EGGRIGHT3_
|
— |
Fault Valve Evap Sol
EGGRIGHT3_
|
— |
Show 6 more fields
| Signal | Unit |
|---|---|
High Disch Pressure
EGGRIGHT3_
|
— |
High Disch Temp
EGGRIGHT3_
|
— |
High Discharge Pressure Cutouts
EGGRIGHT3_
|
— |
High Discharge Temp Cutouts
EGGRIGHT3_
|
— |
Low Disch Pressure
EGGRIGHT3_
|
— |
Low Suction Pressure
EGGRIGHT3_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT3_a160.