EGGRIGHT3_a204 — Right Panel Actuator Unavailable
Full alert identifier: EGGRIGHT3_a204_rightPanelActuatorUnavailable
Alert description
A condition affecting right panel cabin HVAC actuator functionality has been detected.
Potential impact
The HVAC system is unable to control airflow through the right panel vent
Set condition
A condition affecting the right panel HVAC actuator is detected.
Clear condition
Successful HVAC actuator calibration or clear actuator blockages.
Signals to check
These diagnostic fields are associated with EGGRIGHT3_a204. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Calibration Negative Direction
EGGRIGHT3_
|
— |
Calibration Positive Direction
EGGRIGHT3_
|
— |
Connected
EGGRIGHT3_
|
— |
Driver Fault
EGGRIGHT3_
|
— |
Position Actual
EGGRIGHT3_
|
% |
Position Target
EGGRIGHT3_
|
% |
Target Missed
EGGRIGHT3_
|
— |
Uncalibrated
EGGRIGHT3_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT3_a204.