EGGRIGHT3_a569 — Pump Air Lock
Full alert identifier: EGGRIGHT3_a569_pumpAirLock
Alert description
The VCSUPER and EGGRIGHT3 controller detects an air lock in the pump due to smaller than expected pump current values
Potential impact
Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.
Set condition
The pump current is below the minimum threshold value for more than 20 seconds.
Clear condition
The pump current is more than the estimated minimum value for 30 seconds.
Signals to check
These diagnostic fields are associated with EGGRIGHT3_a569. Check the alert's Alert Log in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Chiller Is Dry Run Detected
EGGRIGHT3_
|
— |
Chiller Pump I Phase Filtered
EGGRIGHT3_
|
A |
Chiller Pump I Phase Min Filt
EGGRIGHT3_
|
A |
Chiller Pump Rpm
EGGRIGHT3_
|
rpm |
Powertrain Is Dry Run Detected
EGGRIGHT3_
|
— |
Powertrain Pump I Phase Filtered
EGGRIGHT3_
|
A |
Powertrain Pump I Phase Min Filt
EGGRIGHT3_
|
A |
Powertrain Pump Rpm
EGGRIGHT3_
|
rpm |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT3_a569.