EGGRIGHT3_a569 — Pump Air Lock

Full alert identifier: EGGRIGHT3_a569_pumpAirLock

Alert description

The VCSUPER and EGGRIGHT3 controller detects an air lock in the pump due to smaller than expected pump current values

Potential impact

Cabin climate control system air conditioning may be limited or unavailable. Powertrain performance may be limited.

Set condition

The pump current is below the minimum threshold value for more than 20 seconds.

Clear condition

The pump current is more than the estimated minimum value for 30 seconds.

Signals to check

These diagnostic fields are associated with EGGRIGHT3_a569. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
Chiller Is Dry Run Detected EGGRIGHT3_a569_chillerIsDryRunDetected —
Chiller Pump I Phase Filtered EGGRIGHT3_a569_chillerPumpIPhaseFiltered
255
SNA
A
Chiller Pump I Phase Min Filt EGGRIGHT3_a569_chillerPumpIPhaseMinFilt
127
SNA
A
Chiller Pump Rpm EGGRIGHT3_a569_chillerPumpRpm
255
SNA
rpm
Powertrain Is Dry Run Detected EGGRIGHT3_a569_powertrainIsDryRunDetected —
Powertrain Pump I Phase Filtered EGGRIGHT3_a569_powertrainPumpIPhaseFiltered
255
SNA
A
Powertrain Pump I Phase Min Filt EGGRIGHT3_a569_powertrainPumpIPhaseMinFilt
127
SNA
A
Powertrain Pump Rpm EGGRIGHT3_a569_powertrainPumpRpm
255
SNA
rpm

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT3_a569.

Browse all EGGRIGHT3 alert codes