EGGRIGHT3_a446 — Cabin HVAC Unavailable Context

Full alert identifier: EGGRIGHT3_a446_cabinHVACUnavailableContext

Alert description

Condition(s) affecting the thermal management system have reduced cabin heating and/or cooling performance or made cabin heating and/or cooling unavailable.

Potential impact

Cabin heating and/or cooling performance may be limited, or cabin heating and/or cooling may be unavailable.

Set condition

May set due to many possible conditions affecting thermal management system functionality. Alert log signal data should provide information on specific condition(s).

Clear condition

Condition(s) affecting thermal management system functionality no longer detected.

Signals to check

These diagnostic fields are associated with EGGRIGHT3_a446. Check the alert's Alert Log in Service Mode Plus for available values.

Signal Unit
CCLEXV Not Ready EGGRIGHT3_a446_CCLEXVNotReady —
CCREXV Not Ready EGGRIGHT3_a446_CCREXVNotReady —
LCCEXV Not Ready EGGRIGHT3_a446_LCCEXVNotReady —
Battery Over Temp EGGRIGHT3_a446_batteryOverTemp —
Check A 447 Alert EGGRIGHT3_a446_checkA447Alert —
Chiller EXV Not Ready EGGRIGHT3_a446_chillerEXVNotReady —
Comp Fault Pd High EGGRIGHT3_a446_compFaultPdHigh —
Comp Fault Pd Low EGGRIGHT3_a446_compFaultPdLow —
Show 38 more fields
Signal Unit
Comp Fault Ps Low EGGRIGHT3_a446_compFaultPsLow —
Comp Fault Refrigerant EGGRIGHT3_a446_compFaultRefrigerant —
Comp Fault Td High EGGRIGHT3_a446_compFaultTdHigh —
Comp Standby Coast Down Mode EGGRIGHT3_a446_compStandbyCoastDownMode —
Comp Standby Communication EGGRIGHT3_a446_compStandbyCommunication —
Comp Standby HV Not Ready EGGRIGHT3_a446_compStandbyHVNotReady —
Comp Standby Low Ambient EGGRIGHT3_a446_compStandbyLowAmbient —
Comp Standby Low Disch Press EGGRIGHT3_a446_compStandbyLowDischPress —
Comp Standby Multiple Pd Cutouts EGGRIGHT3_a446_compStandbyMultiplePdCutouts —
Comp Standby Multiple Td Cutouts EGGRIGHT3_a446_compStandbyMultipleTdCutouts —
Comp Standby Refrig Not Ok EGGRIGHT3_a446_compStandbyRefrigNotOk —
Comp Standby Self Not Ready EGGRIGHT3_a446_compStandbySelfNotReady —
Comp Standby Showroom Mode EGGRIGHT3_a446_compStandbyShowroomMode —
Coolant Sys Locked Out EGGRIGHT3_a446_coolantSysLockedOut —
Evap EXV Not Ready EGGRIGHT3_a446_evapEXVNotReady —
Evap Low Ps Cutout EGGRIGHT3_a446_evapLowPsCutout —
High Suction Superheat EGGRIGHT3_a446_highSuctionSuperheat —
Hp Battery Load Type EGGRIGHT3_a446_hpBatteryLoadType
0
NONE
1
BATT HEAT
2
BATT COOL
—
Hp Cabin Load Type EGGRIGHT3_a446_hpCabinLoadType
0
NONE
1
CC
2
REHEAT
3
EVAP
—
Hvac System Fault EGGRIGHT3_a446_hvacSystemFault —
Recirc EXV Not Ready EGGRIGHT3_a446_recircEXVNotReady —
Ref Sys Locked Out EGGRIGHT3_a446_refSysLockedOut —
Sensor Droop Pd EGGRIGHT3_a446_sensorDroopPd —
Sensor Has Offset Pd EGGRIGHT3_a446_sensorHasOffsetPd —
Sensor Has Offset Td EGGRIGHT3_a446_sensorHasOffsetTd —
Sensor Has Offset Tl EGGRIGHT3_a446_sensorHasOffsetTl —
Sensor Intermittent Pd EGGRIGHT3_a446_sensorIntermittentPd —
Sensor Intermittent Pl EGGRIGHT3_a446_sensorIntermittentPl —
Sensor Intermittent Ps EGGRIGHT3_a446_sensorIntermittentPs —
Sensor Intermittent Td EGGRIGHT3_a446_sensorIntermittentTd —
Sensor Intermittent Tl EGGRIGHT3_a446_sensorIntermittentTl —
Sensor Intermittent Ts EGGRIGHT3_a446_sensorIntermittentTs —
Using Modeled Pd EGGRIGHT3_a446_usingModeledPd —
Using Modeled Pl EGGRIGHT3_a446_usingModeledPl —
Using Modeled Ps EGGRIGHT3_a446_usingModeledPs —
Using Modeled Td EGGRIGHT3_a446_usingModeledTd —
Using Modeled Tl EGGRIGHT3_a446_usingModeledTl —
Using Modeled Ts EGGRIGHT3_a446_usingModeledTs —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of EGGRIGHT3_a446.

Browse all EGGRIGHT3 alert codes